Remote Operation
Multichannel Operation (6000 Watt only)
Release 3.0 117
Multichannel
Broadcast
Commands
Add a suffix of "0" to simultaneously broadcast the "command" to the master and all
other units on the CANbus. Only commands are allowed, queries are not allowed.
Note that there will be a lag in execution time between the local unit and all other
units of up to a maximum of 20 ms. For example:
SOURCE0:VOLT 10.0
will set all units in a multichannel string to 10.0 V
Specifications
Max connected units 50
Max cable length 40 m
Bus speed 700 kbits/sec
Termination 120 ohm 1/4 W
Connections parallel male DB9 to female DB9 cable
Addresses 1 to 50