Specifications and Characteristics
Output Performance Specifications
Release 3.0 241
Output Hold-Up Time – Source Interruption
Minimum 4 ms with output deviation less than 5% of maximum output voltage after
source interruption.
Transient Response Time
1
Time to recover within 0.75% of rated output of previous level after step change in
load current between 50% and 100%.
Mode Crossover
Maximum deviation as a percentage of rated output voltage.
Peak–Peak and RMS Noise Bandwidth Limits
The frequency range for Peak to Peak measurements is 10 Hz–20 MHz.
The frequency range for RMS measurements is 10 Hz–100 kHz.
Maximum Remote Sense Line Drop Compensation
Minimum 3.8 V for each line, 5 V typical
Isolation
1. Time for the output voltage to recover within 0.75% of rated output of its previous level
after a step change in load current of up to 50% - 100% and 100% to 50% of rated
output
Mode Time
Voltage Mode 3 ms (6000 W models)
Voltage Mode 35 ms (12000 W models)
CV – CC Overshoot 1%
AC Input to Output 1350 V
ac
AC Input to Chassis 1350 V
ac
Output to Chassis 600 V
ac
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xantrex XDC 10-600 and is the answer not in the manual?

Xantrex XDC 10-600 Specifications

General IconGeneral
BrandXantrex
ModelXDC 10-600
CategoryPower Supply
LanguageEnglish

Related product manuals