7/98
Xerox DocuPrint P8e Service Manual 7-7 Repair Analysis Procedures (RAP)
11 With AC power applied and the Main Drive Motor not running, measure the voltage between pins
1, 2, 5, & 6 and frame ground. The voltage is +24.0 +/- 2.0 VDC on all pins.
YN
| Replace the Main Drive Motor Assembly (PL 9).
12 Replace the following one at a time; the Joint PWB (PL 10), then the Engine Controller PWB (PL
10).