99
Parameter
self-checking cannot
pass
Re-power the servo to restore
default setting or contact us
The setting value out
of range
Check the parameters and set
again
TREF or VREF
function setting
conflict
Check the TREF or VREF
setting
Sampling
channel
setting error
User-defined output
trigger channel or
data monitor channel
setting error
Check the setting parameter
Power supply
voltage too low
1.for single phase 220V,
connect L1, L3
2. power on at once after cut
power supply it will show
E-024
3. set the parameter again
Parameter store error
when power off
Flash chip power
supply not stable
(220V: U0-05
≥390 alarm,
380V: U0-05
power grid voltage
too high
Check the power supply, 220V
servo drive voltage range is
200V~240V, 380V servo drive
voltage range is 360~420V,
please use regulator and