Wireless Access Point
589
Section5.2.2.1(g)XirrusWirelessdeviceshavenoessentialperformanceperIEC
60601‐1‐2. 
Section5.2.2.2–Tables4and6
Table4fornon‐lifesupportingequipment
Guidance and manufacturer’s declaration – electromagnetic immunity
Xirrus wireless devices are intended for use in the electromagnetic environment specified below. 
The customer or the user of the Xirrus device should assure that it is used in such an environment.
Immunity test IEC 60601 test 
level
Compliance 
level
Electromagnetic environment - guidance
Conducted RF
IEC 61000-4-6
Radiated RF
IEC61000-4-3
3 Vrms
150 kHz to 80 
MHz
3 V/m
80 MHz to 2.5 
GHz
3 V
3 V/m
Portable and mobile RF communication 
equipment should be no closer to any part of 
the Xirrus wireless device, including cables, 
than the recommended separation distance 
calculated from the equation applicable to the 
frequency of the transmitter.
Recommended separation distance
d = 1.17* √P
d = 1.17* √P   80 MHz to 800 MHz
d = 2.33* √P   800 MHz to 2.5 GHz
Where P is the maximum output power rating 
of the transmitter in watts (W) according to 
the transmitter manufacturer and d is the 
recommended separation distance in metres 
(m).
Field strengths from fixed RF transmitters, as 
determined by an electromagnetic site 
survey
a
, should be less than the compliance 
level in each frequency range
b
.
Interference may occur in the 
vicinity of equipment marked with 
this symbol: