Xtralis XAS-1-US
Product Guide
October 2016
Document: 20635_08
Part Number: 29875

Questions and Answers

  • J
    Jennifer TrujilloAug 3, 2025
    What to do if FLOW HI or FLOW LO light is on Xtralis XAS-1-US?
    • L
      Leonard MartinAug 3, 2025
      If the FLOW HI or FLOW LO light is illuminated on your Xtralis Smoke Alarm, take the following steps: * Make sure the sampling pipes are correctly installed, the lid is fitted, and the box is fully sealed. * Confirm that the flow calibration procedure has been carried out. * Check and clean the filters. * Verify that the fan is operating normally. * If using flexible tubing, check for pinches or kinks. * For duct applications, ensure the inlet and exhaust tube holes are free from obstructions.
  • C
    Christine WhiteAug 7, 2025
    Why is the Xtralis XAS-1-US Smoke Alarm detector unresponsive to smoke tests?
    • K
      Kara LeeAug 7, 2025
      If your Xtralis Smoke Alarm detectors are unresponsive to smoke tests, consider the following: * Ensure the sampling pipe is correctly installed and undamaged. * Verify that the recommended baffles are fitted. * Confirm that the recommended test method is being used. * Try increasing the fan speed and re-testing.
  • M
    Mrs. Jill PetersonAug 11, 2025
    What to do if the flow reading on Bargraph display moves erratically on Xtralis Smoke Alarm?
    • A
      Alyssa HooverAug 11, 2025
      If the flow reading on the bargraph display of your Xtralis Smoke Alarm moves erratically, decrease the flow sensitivity setting and recalibrate the air flows.
  • R
    reginald67Aug 15, 2025
    What to do if flow reading on Bargraph is unresponsive to broken or blocked pipe on Xtralis XAS-1-US?
    • F
      fordmatthewAug 15, 2025
      If the flow reading on the bargraph display of your Xtralis Smoke Alarm is unresponsive to a broken or blocked pipe, increase the flow sensitivity setting and recalibrate the air flows.
  • S
    Susan SmithAug 20, 2025
    How to fix Xtralis XAS-1-US Smoke Alarm with no lights on display and fan not running?
    • D
      Dr. Gary MckinneyAug 20, 2025
      If there are no lights on the display and the fan is not running on your Xtralis Smoke Alarm, check the following: * Ensure the supply leads are correctly oriented. * Make sure that the BAT FUSE is correctly seated in the socket and that the fuse is not blown.
  • C
    Christine Baker DVMAug 25, 2025
    How to fix Xtralis XAS-1-US Smoke Alarm with no lights on display but fan running OK?
    • Z
      Zachary NealAug 25, 2025
      If there are no lights on the display of your Xtralis Smoke Alarm, but the fan is running OK, ensure that the ribbon cable is fully seated into the main and display boards.
  • B
    baileystaffordAug 28, 2025
    Why is the power light flashing on my Xtralis XAS-1-US?
    • A
      Angel AndersonAug 28, 2025
      If the power light is flashing on your Xtralis Smoke Alarm, ensure the supply to the BATTERY connector is within limits.

Summary

Document Conventions

Codes and Standards Information

Regional Regulatory Requirements (UL)

Details UL listing and suitability for open area protection with specific detector sensitivities.

ULC Listing

Details ULC listing and suitability for open area and duct applications.

Product Listings

Introduction to XAS-1-US System

Detector Installation

Mounting the Detector Enclosure

Guides on properly mounting the detector enclosure, including clearance and safety precautions.

Wiring the XAS-1-US Unit

Details wiring connections, including 24V DC input, fault relay, and wiring examples.

Point Detector Integration

Covers selecting, installing, and using compatible point detectors with the XAS-1-US.

Baffles and Overlabel Application

Explains the use of baffles for airflow and the application of overlabels for compliance.

Pipe Network Installation

Pipe Specification and Components

Details CPVC pipe, flexible tubes, and other components required for pipe network setup.

Sampling Hole and End Cap Configuration

Guides on drilling sampling holes and using end caps for open area and duct applications.

Pipe Network Accessories and Considerations

Covers bends, capillary tubes, exhaust, and filters for pipe network installations.

Open Area Applications Design

Outlines pre-engineered pipe network designs for open area applications, including parameters.

Duct Applications Setup and Accessories

Details accessory lists and installation procedures for duct applications, including probe placement.

System Configuration

Display Functions and Indicators

Explains the icons and indicators present on the XAS-1-US system display for monitoring.

User Interface Operations

Guides on navigating the user interface, setting parameters, and performing functions like calibration.

Parameter Settings for Optimal Performance

Details settings for fan speed, flow delays, and flow sensitivity crucial for system calibration.

System Testing Procedures

Point Detector Testing

Provides methods for testing point detectors in both open area and duct applications.

System Functionality Test

Describes how to test the overall system's functionality, including smoke introduction.

Maintenance and Replacement

Air Inlet Filter Replacement

Step-by-step procedure for replacing the air inlet filter element to maintain airflow.

Point Detector Replacement

Instructions for safely removing and replacing a point detector within the XAS-1-US unit.

Troubleshooting Common Issues

Technical Specifications

Typical Supply Current and Fan Speed

Provides typical current consumption figures for various fan speeds and installation configurations.

Xtralis XAS-1-US Specifications

General IconGeneral
BrandXtralis
ModelXAS-1-US
CategorySmoke Alarm
LanguageEnglish