Xtralis XAS-2-US
Product Guide
October 2016
Document: 20636_08
Part Number: 29876

Questions and Answers

  • B
    Brent MccarthyAug 2, 2025
    What to do if FLOW HI or FLOW LO light is on Xtralis XAS-2-US?
    • G
      ggillAug 2, 2025
      If the FLOW HI or FLOW LO light is illuminated on your Xtralis Smoke Alarm, take the following steps: * Make sure the sampling pipes are correctly installed, the lid is fitted, and the box is fully sealed. * Confirm that the flow calibration procedure has been carried out. * Check and clean the filters. * Verify that the fan is operating normally. * If using flexible tubing, check for pinches or kinks. * For duct applications, ensure the inlet and exhaust tube holes are free from obstructions.
  • S
    Samantha DavisAug 6, 2025
    Why is the Xtralis XAS-2-US Smoke Alarm detector unresponsive to smoke tests?
    • E
      Eddie MillerAug 7, 2025
      If your Xtralis Smoke Alarm detectors are unresponsive to smoke tests, consider the following: * Ensure the sampling pipe is correctly installed and undamaged. * Verify that the recommended baffles are fitted. * Confirm that the recommended test method is being used. * Try increasing the fan speed and re-testing.
  • B
    Blake WatsonAug 10, 2025
    What to do if the flow reading on Bargraph display moves erratically on Xtralis Smoke Alarm?
    • J
      juan96Aug 10, 2025
      If the flow reading on the bargraph display of your Xtralis Smoke Alarm moves erratically, decrease the flow sensitivity setting and recalibrate the air flows.
  • S
    stephengriffinAug 15, 2025
    What to do if flow reading on Bargraph is unresponsive to broken or blocked pipe on Xtralis Smoke Alarm?
    • W
      William MooreAug 15, 2025
      If the flow reading on the bargraph display of your Xtralis Smoke Alarm is unresponsive to a broken or blocked pipe, increase the flow sensitivity setting and recalibrate the air flows.
  • A
    Amber RodgersAug 19, 2025
    How to fix Xtralis XAS-2-US with no lights on display and fan not running?
    • C
      Chad ContrerasAug 19, 2025
      If there are no lights on the display and the fan is not running on your Xtralis Smoke Alarm, check the following: * Ensure the supply leads are correctly oriented. * Make sure that the BAT FUSE is correctly seated in the socket and that the fuse is not blown.
  • B
    Barbara PopeAug 25, 2025
    How to fix Xtralis XAS-2-US with no lights on display but fan running OK?
    • A
      allendavidAug 25, 2025
      If there are no lights on the display of your Xtralis Smoke Alarm, but the fan is running OK, ensure that the ribbon cable is fully seated into the main and display boards.
  • D
    Debra GreeneAug 28, 2025
    Why is the power light flashing on my Xtralis XAS-2-US Smoke Alarm?
    • C
      Charles SpencerAug 28, 2025
      If the power light is flashing on your Xtralis Smoke Alarm, ensure the supply to the BATTERY connector is within limits.

Summary

Introduction

Detector Installation

Mounting the Detector Enclosure

Details the procedure for mounting the detector enclosure to a surface.

Wiring

Explains the wiring connections for the XAS-2-US unit.

Point Detectors

Lists tested and certified point detectors for the XAS-2-US system.

Point Detector Selection

Details the selection criteria and compatibility of point detectors with the XAS-2-US.

Point Detector Installation

Explains how to install point detectors into the XAS-2-US unit.

Overlabel Application

Details the process of applying overlabels to the XAS-2-US for compliance.

Pipe Network Installation

Pipe Specification

Specifies the requirements for CPVC and flexible tubing for the sampling pipe.

Sampling Holes and End Caps

Details sampling hole drilling and the use of end caps.

Open Area Applications

Describes the standard configuration for open area sampling systems.

Duct Applications

Details the use of flexible tubes and CPVC pipes for duct installation.

Configuration

Display Functions

Describes the functional LEDs and their meanings on the XAS-2-US unit.

User Interface

Explains how to navigate and use the XAS-2-US system's interface and functions.

Parameters

Details the fan speed, flow limits, and flow sensitivity settings for installation.

Testing

Point Detectors

Describes testing procedures for point detectors in open area and duct applications.

System

Outlines the system-level testing requirements for the XAS-2-US.

Maintenance

Air Inlet Filter Replacement Procedure

Provides step-by-step instructions for replacing the air inlet filter.

Point Detector Replacement

Details the procedure for safely removing and replacing point detectors.

Troubleshooting

Specifications

Typical Supply Current & Fan Speed

Presents typical current consumption figures for different fan speeds.

Xtralis XAS-2-US Specifications

General IconGeneral
BrandXtralis
ModelXAS-2-US
CategorySmoke Alarm
LanguageEnglish