EasyManua.ls Logo

XtremepowerUS 75210 - Troubleshooting

XtremepowerUS 75210
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pool Heater Not Running:
If the heat pump control is set to off
Turn it on
If the desired water temperature is reached
The unit will automatically restart when the water temperature drops below the set point
If the main breaker is tripped
Reset it and restart the heater
If the filter is dirty and restricting water flow
Backwash and clean the filter
Fan Running, But Compressor Not:
If the heat pump is in protection mode
There may be a delay before restarting
If the unit is on a defrost cycle
The compressor will automatically start again after a few minutes unless it stops three
times continuously
No Display and Fan Not Running, But Compressor Is:
Have an electrician verify the heat pump's power supply by checking the L1/L2/L3 connec-
tions in the unit's service box.
Water Around the Unit:
Condensation during the heating mode is normal. To check for leaks, stop the heater, keep
the pool pump running for over 5 hours, and if water still comes out, contact your dealer for
service.
Heater Running, But Desired Water Temperature Not Reached:
Heat loss may be too significant
Cover your pool as often as possible
If the evaporator is restricted due to improper location or is dirty
Clean it by running tap water over the coil without a nozzle attachment.
Do not use pressurized water.
Adjust water flow if restricted.
Should the pool heater fail to operate due to unforeseen issues not listed above, seek assis-
tance from qualified professionals for a thorough examination and resolution.
TROUBLESHOOTING
13
TROUBLESHOOTING
WARNING

Related product manuals