PRODUCT INFORMATION
5
SPECIFICATION
75210 75211 75212
MAX FUSE 25A 50A 70A
MCA 16A 34A 54A
MEASURING CONDITIONS HEATING CAPACITY KW 15.5 19 40.1
A 27/24.3 W 26.7/28.7 BTU / H 53000 65000 137000
(A 80.6 80% W 80 ) INPUT POWER KW 2.3 3 6.3
RUNNING CURRENT A 10.8 13.2 27.4
COP 6.7 6.2 6.4
MEASURING CONDITIONS HEATING CAPACITY KW 14.6 17.9 37.7
A 27/21.8 W 26.7/28.7 BTU / H 49820 61100 128780
(A 80.6 63% W 80 ) INPUT POWER KW 2.8 3.3 6.5
RUNNING CURRENT A 12.6 14.9 29.8
COP 5.3 5.5 5.8
MEASURING CONDITIONS HEATING CAPACITY KW 8.7 10.7 22.5
A 10/6.8°C W 26.7/28.7°C BTU / H 29680 36400 76720
(A 50 63% W 80 ) INPUT POWER KW 2.2 2.5 5.4
RUNNING CURRENT A 10.2 11.6 24.5
COP 3.9 4.2 4.2
V/PH / HZ 208-230 / 1PH / 60HZ 208-230 / 1PH / 60HZ 208-230 / 1PH / 60HZ
KW 3.6 4.3 8.6
A 17.3 20.5 41.2
ROTARY SCROLL SCROLL
R410A R410A R410A
W 210 250 560
INCH 19.7 19.7 24.8
INCH 2 2 2
GPM 23-33 29-39 60-70
PSI 0.87 1.16 2.46
SPA GALLON 2641 3434 9246
POOL GALLON 10566 12944 27209
PRODUCT DIMENSION L / W / H INCH 27.2 X 27.2 X 29.9 27.2X 27.2 X 37.8 INCH 32.7 X 32.5 X 44
NET WEIGHT LBS 152 209 282
INPUT POWER OF FAN
FAN LEAF DIMENSION
WATER CONNECTION (MALE COUPLING)
ADVISED VOLUME
WATER FLOW RATE
WATER PRESSURE DROP
POWER SUPPLY
MAX HEATING INPUT
MAX HEATING CURRENT
COMPRESSOR
REFRIGERANT
LEAKAGE PROTECTION CIRCUIT BREAKER
SKU (MODEL) NUMBER