Installation, Operation, and
Maintenance
898397_4.0
2008 Ready 8, 8S

Questions and Answers

  • R
    Richard HowellAug 12, 2025
    What to do if the Xylem Water Pump runs but the motor protection trips?
    • G
      greerrobinAug 12, 2025
      If the Xylem Water Pump runs, but the motor protection trips, first, adjust the motor protection according to the data plate and cable chart, if applicable. If the impeller is difficult to rotate, clean the impeller and the sump, and ensure the impeller is properly trimmed. Also, check the fuses and replace any that have tripped. If the fuses are intact, contact a certified electrician.
  • G
    George MannAug 16, 2025
    What to do if Xylem Water Pump delivers too little or no water?
    • K
      Kelly KnightAug 16, 2025
      If the Xylem Water Pump delivers too little or no water, first check the valves and reset any that are incorrectly positioned, replacing them if necessary. Ensure all valves are installed correctly according to media flow and open properly. Clean out any obstructions in the pipes and seal any leaks in the pipes and joints. If the impeller is difficult to rotate by hand, clean the impeller and the sump, and ensure the impeller is properly trimmed. If it is a 1-phase pump and the impeller rotates in the wrong direction, contact a sales or authorized service representative.
  • D
    Diana KennedyAug 20, 2025
    How to troubleshoot if the Xylem Water Pump does not start?
    • A
      Arthur WilliamsonAug 20, 2025
      If the Xylem Water Pump does not start, and an alarm signal has been triggered on the control panel, make sure that the impeller rotates freely, the sensor indicators do not indicate an alarm, and the overload protection is not tripped. If the pump does not start automatically but can be started manually, verify that the start level regulator is functioning (clean or replace if needed), all connections are intact, the relay and contactor coils are intact, and the control switch (Man/Auto) makes contact in both positions. Check the control circuit and functions.
  • K
    Kelly HolmesAug 25, 2025
    What to do if Xylem Water Pump starts-stops-starts in rapid sequence?
    • J
      Joseph HerreraAug 25, 2025
      If the Xylem Water Pump starts and stops in rapid sequence, check that the distance between the start and stop levels is sufficient, the non-return valve(s) work(s) properly, and the length of the discharge pipe between the pump and the first non-return valve is sufficiently short. Also, check the contactor connections, the voltage in the control circuit, the functioning of the stop-level regulator, and whether the voltage drop in the line at the starting surge causes the contactor's self-holding malfunction.
  • S
    Sara ButlerAug 27, 2025
    What to do if Xylem Water Pump does not stop when a level sensor is used?
    • W
      William JamesAug 27, 2025
      If the Xylem Water Pump does not stop when a level sensor is used, check for leaks from the piping or discharge connection, ensure the impeller is not clogged, verify the non-return valve(s) are functioning properly, and confirm the pump has adequate capacity. Additionally, clean the level regulators, check their functioning, inspect the contactor and the control circuit, and replace any defective items. If the stop level is set too low, raise it.
  • N
    Nicholas BellAug 31, 2025
    What to do if Xylem Water Pump installation is not receiving voltage?
    • C
      Cassidy ChenAug 31, 2025
      If the Xylem Water Pump installation is not receiving voltage, check that the main power switch is on, there is control voltage to the start equipment, the fuses are intact, there is voltage in all phases of the supply line, all fuses have power and are securely fastened to the fuse holders, the overload protection is not tripped, and the motor cable is not damaged.
  • M
    Michael MathewsSep 4, 2025
    How to fix a liquid level that is too low in Xylem Water Pump?
    • T
      Trevor GreenSep 4, 2025
      To fix the liquid level being too low in your Xylem Water Pump, check that the level sensor is set correctly. Depending on the installation type, add a means for priming the pump, such as a foot valve.
  • M
    Michael MejiaSep 7, 2025
    What to do if there are signs of wear on the impeller, pump, and casing of Xylem Water Pump?
    • L
      lbrownSep 7, 2025
      To address signs of wear on the impeller, pump, and casing of the Xylem Water Pump, replace the worn parts.

Summary

Introduction and Safety

1.2 Safety terminology and symbols

Explanation of safety messages, hazard levels, and warning symbols.

1.3 User safety

Guidelines for site safety, qualified personnel, and personal protective equipment.

1.4 Special hazards

Covers specific hazards in temporary installations and biological risks.

Installation

4.1 Install the pump

Covers pump installation safety, hazards, regulations, and sedimentation prevention.

4.1.1 Install with S-installation

Step-by-step guide for installing the pump using the S-installation method.

4.2 Make the electrical connections

Essential requirements and precautions for making electrical connections.

4.2.1 Connect the motor cable to the pump

Detailed procedure for securely connecting the motor cable to the pump.

4.3 Check the impeller rotation

Instructions to verify the correct direction of impeller rotation after installation.

Operation

5.1 Precautions

Critical checks and warnings before operating the pump.

5.2 Start the pump

Procedure for safely starting the pump, including necessary checks.

Maintenance

6.1 Torque values

Tables specifying correct torque values for screws and nuts during assembly.

Troubleshooting

7.1 The pump does not start

Diagnosing and resolving issues when the pump fails to initiate operation.

7.2 The pump does not stop when a level sensor is used

Troubleshooting why the pump continues to run despite a level sensor signal.

7.5 The pump delivers too little or no water

Diagnosing and fixing problems related to low or no water output.

Xylem Flygt 2008 Ready 8S Specifications

General IconGeneral
Model2008 Ready 8S
CategoryWater Pump
Power0.8 kW
Voltage230 V
Frequency50 Hz
Max Head8 m
Weight12 kg
Protection ClassIP68
Impeller TypeSemi-open
Maximum Submersion Depth10 m
Maximum Liquid Temperature40°C
Specific Gravity of the Liquid1.0
Stator Insulation ClassF
TypeSubmersible
Motor ProtectionThermal Protection
Starting MethodDirect on line
Supply Cable10 m
Max Flow8 m³/h