6 Maintenance
Precautions
Before starting work, make sure that the safety instructions in the chapter Introduction and
Safety on page 3 have been read and understood.
DANGER: Crush Hazard
Moving parts can entangle or crush. Always disconnect and lock out power before
servicing to prevent unexpected startup. Failure to do so could result in death or serious
injury.
Equipment
locked out by
Name .......................
DANGER
WARNING: Biological Hazard
Infection risk. Rinse the unit thoroughly with clean water before working on it.
CAUTION: Crush Hazard
Make sure that the unit cannot roll or fall over and injure people or damage property.
Make sure that you follow these requirements:
Check the explosion risk before you weld or use electrical hand tools.
Allow all system and pump components to cool before you handle them.
Make sure that the product and its components have been thoroughly cleaned.
Make sure that the work area is well-ventilated before you open any vent or drain
valves, remove any plugs, or disassemble the unit.
Do not open any vent or drain valves or remove any plugs while the system is
pressurized. Make sure that the pump is isolated from the system and that pressure is
relieved before you disassemble the pump, remove plugs, or disconnect piping.
Ground continuity verification
A ground (earth) continuity test must always be performed after service.
Maintenance guidelines
During the maintenance and before reassembly, always remember to perform these
tasks:
Clean all parts thoroughly, particularly O-ring grooves.
Change all O-rings, gaskets, and seal washers.
Lubricate all springs, screws, O-rings with grease.
During the reassembly, always make sure that existing index markings are in line.
The reassembled drive unit must always be insulation-tested and the reassembled pump
must always be test-run before normal operation.
6 Maintenance
20 2008 Ready 8, 8S Installation, Operation, and Maintenance

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xylem Flygt 2008 Ready 8S and is the answer not in the manual?

Xylem Flygt 2008 Ready 8S Specifications

General IconGeneral
BrandXylem
ModelFlygt 2008 Ready 8S
CategoryWater Pump
LanguageEnglish

Related product manuals