Lifting equipment
The lifting equipment must fulfill the following requirements:
The minimum height between the lifting hook and the floor must be sufficient to lift the
unit out of the sump. Contact Xylem for information.
The lifting equipment must be able to hoist the unit straight up and down in the sump,
preferably without the need for resetting the lifting hook.
The lifting equipment must be securely anchored and in good condition.
The lifting equipment must support the entire assembly and must only be used by
authorized personnel.
Two sets of lifting equipment must be used to lift the unit for repair work.
The lifting equipment must be dimensioned to lift the unit with any remaining pumped
media (liquid) in it.
The lifting equipment must not be oversized.
NOTICE:
Oversized lifting equipment could cause damage if the unit should stick when being
lifted.
Store the unit
1. After raising the unit, allow it to run for a short time to discharge all remaining pumped
media (liquid).
The unit is frost-proof while operating or immersed in liquid, but the impeller and the
shaft seal may freeze if the unit is raised in a temperature below freezing.
2. Store the unit in a covered and dry location free from heat, dirt, and vibrations.
3. If the unit is stored more than 6 months, rotate the shaft every other month to prevent
the seals from sticking together.
4. Before operating the unit after storage:
If... Then…
the unit has been stored more than 6
months
inspect the unit with special attention to the seals and the cable entry.
the impeller is frozen thaw the impeller by immersing the unit in liquid.
NOTICE:
Never use a naked flame to thaw the unit.
Transportation and Storage
10 Flygt 3201 Installation, Operation, and Maintenance Manual