ecocirc PRO Installation, Operation and Maintenance Manual 21
5 Use and Operation
5.1 Precautions
WARNING
Make sure that the discharged liquid cannot cause damage to persons or things.
WARNING: Electrical hazard
Check that the unit is properly connected to the mains power supply.
WARNING: Hot surface hazard
Motor housing may be very hot. Burn hazard. Do not touch.
NOTICE:
Dry run of the unit is prohibited, as this can destroy the bearings in a very short time.
NOTICE:
It is prohibited to operate the unit with the shut-off valve closed.
5.2 Before starting
Before ever starting the pump, verify that:
The instructions in section
Installation on page 14 have been performed.
The system has been flushed thoroughly to prevent foreign objects and impurities from
blocking the pump.
The system has been filled and air purged (see section
Air Purge on page 22).
5.3 First starting
1. Connect the plug to the mains.
In case of models without potentiometer knob, the pump starts to operate immediately.
In case of models with potentiometer knob the unit stays idle (Standby mode) or starts to
operate depending on the position of the knob (see
Figure 9 for the different scale layouts).
Figure
9
2. With the unit in operation, check that:
No liquid is leaking from the pipes.
There is no unwanted noise or vibrations.
Liquid is actually being pumped.