en – Original Instructions
ecocirc PRO – Installation, Operation and Maintenance Manual 9
3 Technical Description
3.1 Designation
Domestic hot water circulation pump for drinking water only (EU Regulation No. 622/2012).
OEM applications
For special OEM applications the pump has customized versions, which differ from the standard
versions in one or more features of the followings:
• Special software functions
• Customized power supply cable (special connectors or terminals)
• Alternative circulating fluid
3.2 Integrated features and functions
Identification based on part number:
60A
0
1
…
60A
2
…
3
4
…
60A
5
…
6
…
Fix speed
Variable speed
PWM control
Temperature control
Timer control
Standby mode
Air purge function
Error code flashing LED light
Dry run protection
Power Down Reset
*
The function is available only in models with potentiometer knob
**
The function is available only in special OEM models
Identification based on model description:
15-
/
65B
15-
/
65S
-
/
110MB
15-
/
110LB
00-
/
000
Brass pump housing
Stainless steel pump housing
No pump housing (replacement part)
Integrated shut-off valve
Integrated check valve
Internal G1/2 thread connections
External G3/4 thread connections
External G1 1/4 thread connections