10. Troubleshooting
Maintenance and repair operations must be carried out by qualified personnel. Before
servicing the set, disconnect the power supply and make sure there is no pressure in the
The frequency converter memorizes the last alarms triggered. Refer to the frequency converter operating
instructions for the types of malfunctions and directions on how to view the last alarms triggered.
1. Power supply disconnected
2. Switch in OFF position
1. Power supply disconnected
2. Triggering of motor thermal
protector
3. Frequent startups
and stops
4. The motor runs but
no water is
delivered
1. No water on suction side or inside
pump
Fill the pump or suction piping /
open the on-off valves
2. Air in suction piping or pump
Bleed the pump, check the
suction connections.
3. Loss of pressure on suction side
Check the NPSH and, if
necessary, modify the system
1. Defective mechanical seal
Replace the mechanical seal
2. Undue mechanical stress on
pump
1. Water return when pumps stop
3. Pump rotation hindered
Check for undue mechanical
stress on pump