EasyManua.ls Logo

Yale 6116 Series

Yale 6116 Series
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 6
Copyright ©2015 Yale Security Inc., an ASSA ABLOY Group Company. All rights reserved. Reproduction
in whole or in part without the express written permission of Yale Security Inc. is prohibited.
An ASSA ABLOY Group Brand.
Exit Devices
6116 Series
For technical support, contact Y ale
®
at
800.438.1951 x5033 or support@y alelocks.com
80-9460-6011-000 11/18
6. Push the alarm assembly into the cover skirt assembly (Figure 4B).
7. Insert the cylinder, collar (if required) and activator and nut. Tighten nut. Be sure that the activator is sitting properly
and can move freely.
8. Be sure the LED aligns with the LED opening on the Cover Skirt Assembly.
9. Screw the Lock Washer into the Cover Skirt Assembly.
E Activate & Test New Alarm Assembly
Continued from the previous page...
1. Remove the Rear End Cap using a #2 square socket screwdriver (Figure 5A).
F Mounting the Switch Lever
Continued on the next page...
Figure 4B - Alarm Assembly
Lock Washer
6-32 x 3/8˝ PPHMS
Figure 5A - Removing the Rear End Cap
Device
Assembly
Rear End Cap
Square Socket
Screws