Table 8. (See Figure 18 through Figure 27) (Continued)
Item
No.
Item
8 Hr/
1 Day
250 Hr/
6 Mo
500 Hr/
6 Mo
1000
Hr/
6 Mo
2000 Hr/
1 Yr
4000 Hr/
2 Yr
Procedure or
Quantity
Specification
NOTE 13: Replace after 3000 hours. Use hour interval only.
NOTE
14: Use Ethylene Glycol Boron-free Antifreeze. Purchase a pre-diluted 50/50 solution; or mix 50% concentrate with 50% distilled or deionized water.
NOTE 15: Hydraulic oil sampling and analysis is a recommended practice. See Hydraulic Cleanliness Procedures 1900 YRM 1620 for oil cleanliness
and water content guidelines. For lift trucks operating in heavy duty applications or highly contaminated environments, take oil samples every 500 hours.
Normal operating conditions may allow for less frequent oil sampling. Oil sampling should be done just prior to all oil and filter changes.
X = Check C = Change L = Lubricate CIL = Check indicator light during operation