equipped with Mazda LPG engine (except Mazda 2007
emission compliant engines).
NOTE: The warm-up/thaw cycle can be bypassed at any-
time by cranking the engine normally.
2. Turn/push the key button to the ON position but do not
crank the engine.
3. The Engine Control Unit (ECU) will automatically begin a
warm-up/thaw cycle which preheats select fuel system
components.
4. Do not attempt to start the engine for approximately 1
minute.
5. Start the engine using the cranking key button. Use of
the accelerator pedal may assist in starting and keeping the
engine running, until warmed.
6. If engine fails to start, turn the key to the OFF position for
at least 30 seconds, then repeat procedure insuring that 1
minute delay has been observed.
7. Make sure the parking brake is applied or push on the
inching/brake pedal.
8. If equipped, put the direction control lever for the trans-
mission in the NEUTRAL (N) position.
9. Make sure lift truck hood is closed.
10. Depress and release the Power ON/OFF button. If lift
truck is equipped with a diesel engine and engine is cold,
the cold start indicator light will illuminate and the cold start
circuit will be energized.
11. If the truck is equipped with Operator Password feature,
enter correct operator, supervisor, or service password.
12. On trucks equipped with a LPG or gasoline engine,
press and hold the Engine Start button to engage the
starter. The word "Cranking" and a 30-second countdown
timer will appear on the LCD screen when the Engine Start
button is pressed.
On trucks equipped with a diesel engine, if cold start delay
is required, the cold start indicator will be illuminated and a
countdown time of ten seconds is displayed. When count-
down reaches 0, press and hold the Engine Start button to
engage the starter.
For all engine types, if engine fails to start after 30 sec-
onds, the starter will shutdown for 60 seconds to cool off. A
60-second countdown timer will appear on the LCD screen
showing the time remaining before a restart attempt can be
tried. To restart engine, repeat Step 10
through Step 12.
Operating Procedures
73

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yale VERACITOR GCC030VX and is the answer not in the manual?

Yale VERACITOR GCC030VX Specifications

General IconGeneral
BrandYale
ModelVERACITOR GCC030VX
CategoryForklifts
LanguageEnglish

Related product manuals