Table 6. (See Figure 17 Through Figure 20) (Continued)
Item No. Item
8 Hr/
1 Day
250 Hr/
6 Mo
500 Hr/
6 Mo
1000 Hr/
6 Mo
2000 Hr/
1 Yr
4000 Hr/
2 Yr
Procedure
or Quantity
Specification
20 PCV VALVE
Kubota 2.5L
X Check Only.
Replace as
Necessary.
See NOTE
15.
See Parts Manual.
OXYGEN SENSOR X Check Indicator Light
30 VALVE ADJUSTMENT
Yanmar 2.6L and 3.3L
Diesel Engines
X Adjust as
Required.
Intake
0.20 mm (0.008 in.)
Cold Exhaust
0.20 mm (0.008 in.)Cold
30 VALVE ADJUSTMENT
Kubota 2.5L (LPG)
X Adjust as
Required.
Intake and Exhaust Cold
0.18 to 22 mm (0.007 to
0.0086 in.)
30 VALVE ADJUSTMENT
Kubota 2.4L (Diesel)
X Adjust as
Required.
Intake and Exhaust Cold
0.18 to 22 mm (0.007 to
0.0086 in.)
4 DIRECT ELECTRONIC
PRESSURE REGULATOR
(DEPR)
PSI 2.4L Engine
X Check Condi-
tion.
Replace as
Necessary.
See Parts Manual.
X = Check C = Change L = Lubricate CIL = Check indicator light during operation
Maintenance Schedule
124

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yale Veracitor GCC040VX and is the answer not in the manual?

Yale Veracitor GCC040VX Specifications

General IconGeneral
BrandYale
ModelVeracitor GCC040VX
CategoryLifting Systems
LanguageEnglish

Related product manuals