Add Air to Pneumatic Tubeless Tire
WARNING
Add air pressure to the tires only in a safety cage. See
Figure 41. Inspect the safety cage for damage before use.
When air pressure is added, use a chuck that fastens
onto the valve stem. Make sure there is enough hose to
permit the operator to stand away from the safety cage
when air pressure is added to the tire. Do not sit or stand
by the safety cage.
Add air to tire to the recommended pressure that is shown on
the Nameplate. Install valve cap to ensure air stays in the tire.
Figure 41. Add Air to Tubeless Tire
Install the Wheels
Install the wheel on the hub. Tighten the nuts in a cross pat-
tern and torque to 450 to 500 N•m (332 to 369 lbf ft) for drive
wheel nuts and 155 to 175 N•m (114 to 129 lbf ft) for steer
wheel nuts. If the wheels are the two-piece rims, make sure
the nuts that fasten the rim halves together are toward the
hub when they are installed.