WARNING
Gasoline is extremely flammable. Do not start the engine
if a gas leak is detected.
1. If the lift truck uses LPG fuel, open the fuel valve on the
LPG tank.
NOTE: The warm-up/thaw cycle can be bypassed at anytime
by cranking the engine normally.
2. Turn/push the key button to the ON position but do not
crank the engine.
3. The Engine Control Unit (ECU) will automatically begin a
warm-up/thaw cycle which preheats select fuel system com-
ponents.
4. Do not attempt to start the engine for approximately 1
minute.
5. Start the engine using the cranking key button. Use of the
accelerator pedal may assist in starting and keeping the
engine running, until warmed.
6. If engine fails to start, turn the key to the OFF position for
at least 30 seconds, then repeat procedure insuring that 1
minute delay has been observed.
7. Make sure the parking brake is applied or push on the
inching/brake pedal.
8. If equipped, put the direction control lever for the trans-
mission in the NEUTRAL (N) position.
9. Make sure lift truck hood is closed.
10. Depress and release the Power ON/OFF button. If lift
truck is equipped with a diesel engine and engine is cold, the
cold start indicator light will illuminate and the cold start circuit
will be energized.
11. If the truck is equipped with Operator Password feature,
enter correct operator, supervisor, or service password.
12. On trucks equipped with a LPG or gasoline engine, press
and hold the Engine Start button to engage the starter. The
word "Cranking" and a 30-second countdown timer will
appear on the LCD screen when the Engine Start button is
pressed.
On trucks equipped with a diesel engine, if cold start delay is
required, the cold start indicator will be illuminated and a
countdown time of ten seconds is displayed. When count-
down reaches 0, press and hold the Engine Start button to
engage the starter.
Operating Procedures
69

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Yale Veracitor GCC040VX and is the answer not in the manual?

Yale Veracitor GCC040VX Specifications

General IconGeneral
BrandYale
ModelVeracitor GCC040VX
CategoryLifting Systems
LanguageEnglish

Related product manuals