3. Command Communication for System Function
3.1 Power on
(1) Power on by RX “STANDBY/ON” key operation
RX turns on the power by RX “STANDBY/ON” key and at the same time CD also turns on the power if CD
state is power on at the last RX power on.
RX unit
CD unit
RX "STANDBY/ON" key
operation
Power on process
[Standby state]
[Power shut down]
Power supply through AC OUTLET
Reset start
initialize process
Initialize complete
PORT_PRE_STANDBY
POWER_ON command if necessary *
PORT_STOP
Power on process
PORT_STANDBY
(2) Power on of individual unit by each “STANDBY/ON” key operation
In the system power on, the each unit can be changed into standby and then into power on again by the
“STANDBY/ON” key operation of the unit.
When the power supply of the unit is individually supplied, only the unit can turn on the power by operating
“STANDBY/ON” key of an individual unit even in system standby.
RX unit CD unit
[Standby state]
CD "STANDBY/ON"
key operation
PORT_STOP
Power on process
* RX transmits POWER_ON command if CD state at the last RX power on is power on.