Vertical Pressure Steam Sterilizer
SM520/820
SM530/830
First Edition
Thank you for purchasing SM series vertical pressure steam steriizer of Yamato
Scientific.
To use this unit properly, read this "Instruction Manual" thoroughly before using
this unit.
Keep this instruction manual around this unit for referring at anytime.
WARNING!:
Carefully read and thoroughly understand the important warning items
described in this manual before using this unit.
Yamato Scientific America Inc.

Questions and Answers

  • K
    kevinwatsonAug 17, 2025
    Why won't the sterilization temperature or pressure rise in my Yamato Laboratory Equipment?
    • C
      Christine KleinAug 17, 2025
      If the sterilization temperature or pressure inside the chamber of your Yamato Laboratory Equipment isn't rising, several factors could be at play. It could be that the preset value is lower than the current temperature inside the chamber, in which case you should adjust the preset value. Also, verify that the power supply voltage is adequate and that the ambient temperature isn't too low. Ensure the cover is securely closed and inspect the packing or flange for any damage.
  • S
    Stephanie Schneider DVMAug 20, 2025
    How to troubleshoot a Yamato Laboratory Equipment that won't start?
    • D
      douglasisaacAug 20, 2025
      If your Yamato Laboratory Equipment isn't starting even with the leakage breaker on, make sure the power cable is properly connected to the power supply. Also, check to see if there is a power outage or if the power voltage is correct.
  • J
    Jeffrey PriceAug 22, 2025
    What to do if too much vapor blows out of my Yamato Laboratory Equipment?
    • D
      Donald SimmonsAug 22, 2025
      If your Yamato Laboratory Equipment is expelling too much vapor or hot water from the drain bottle, check the cooling water box to ensure it contains water and that the water isn't hot. Make sure the exhaust hose isn't removed or broken, the silicon plug is securely fitted, and the water level in the cooling water box is not above the drain level.
  • C
    Charles ShieldsAug 26, 2025
    Why does the temperature change during operation of my Yamato Laboratory Equipment?
    • T
      theresakingAug 26, 2025
      If the temperature fluctuates during operation of your Yamato Laboratory Equipment, ensure that an adequate preset temperature is set. Also, check the power supply voltage and the ambient temperature to see if variations are too large.
  • M
    martinjenniferAug 28, 2025
    What causes exhaust failure in Yamato Laboratory Equipment?
    • T
      thompsonkariAug 28, 2025
      If you're experiencing exhaust failure or the safety valve is activated on your Yamato Laboratory Equipment, check the hose to the cooling water box for any twists or clogs. Also, inspect the exhaust outlet inside the chamber to ensure it isn't blocked by sterile samples and verify that you haven't stored too many samples.
  • J
    Justin MorrowAug 31, 2025
    What to do if the cover of my Yamato Laboratory Equipment does not open?
    • M
      Michael LynchAug 31, 2025
      If the cover of your Yamato Laboratory Equipment won't open, first ensure that the power is turned on. If it is, check whether the sterilization process has been completed. If not, wait for it to finish.
  • S
    Stacy ThompsonSep 2, 2025
    Why is pressure rising in my Yamato Laboratory Equipment chamber when the solenoid valve is open?
    • B
      barbara39Sep 2, 2025
      If the pressure inside the chamber of your Yamato Laboratory Equipment rises even when the solenoid valve is open, check the exhaust outlet inside the chamber to ensure it is not blocked.
  • R
    Rachel HallSep 5, 2025
    Why does my Yamato Laboratory Equipment halt in standby state?
    • P
      Patrick HartmanSep 5, 2025
      If your Yamato Laboratory Equipment halts in standby state, ensure that the cover is securely closed.
  • W
    wbassSep 8, 2025
    Why is my Yamato Laboratory Equipment leaking water?
    • A
      ashley72Sep 8, 2025
      If your Yamato Laboratory Equipment is leaking water, check to make sure the drain valve is securely closed.
  • R
    Robert WiseSep 12, 2025
    Why is my Yamato Laboratory Equipment making a large noise during air purge?
    • B
      bproctorSep 12, 2025
      If your Yamato Laboratory Equipment is making a lot of noise during air purge, verify that the silencer is installed. Also, check the connection of the silencer inside the cooling water box.

Summary

1. Safety Precautions

Illustrated Symbols Overview

Displays various warning, caution, prohibition, and compulsion symbols used in the manual.

General Warnings and Cautions

Covers critical safety instructions for operation, handling, and electrical safety.

2. Before Using

Installation Precautions

Guidelines for selecting a proper installation location and ensuring stability.

Electrical and Power Handling

Instructions for choosing the correct power source, grounding, and handling the power cord safely.

Preparation Before Operation

Step-by-step guide to prepare the sterilizer for its first use.

3. Description and Function of Each Part

4. Operation Method

Operation Course: Liquefy & Retain Temp.

Step-by-step guide for the liquefy and retain temperature operation.

Operation Course: Sterilize & Retain Temp.

Step-by-step guide for sterilize and retain temperature operation.

Operation Course: Instrument Sterilize

Step-by-step guide for sterilizing instruments.

Operation Course: Fluid Sterilize

Step-by-step guide for sterilizing fluids.

Operation Course: Instrument Dry

Step-by-step guide for instrument drying.

Operation Course: Sterilize & Dry

Step-by-step guide for sterilize and dry operation.

5. Handling Precautions

6. Maintenance Method

7. Long Storage and Disposal

8. In the Event of Failure

Safety Device and Error Codes

Lists safety devices, error codes, and their causes/solutions.

9. After-sales Service and Warranty

10. Specification

11. Wiring Diagram

12. Piping Diagram

13. Replacement Parts Table

14. List of Dangerous Substances

15. Installation Standard Manual

16. Maintenance and Replacement

17. Regular Spot Check

Yamato SM530 Specifications

General IconGeneral
BrandYamato
ModelSM530
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals