YASKAWA Europe TOEP C710606 15C YASKAWA AC Drive - V1000 Quick Start Guide EN i
ENGLISH
Quick Start Guide
YASKAWA AC Drive V1000
Compact Vector Control Drive
Models:
200 V Class, Three-Phase Input: 0.1 to 18.5 kW
200 V Class, Single-Phase Input: 0.1 to 4.0 kW
400 V Class, Three-Phase Input: 0.2 to 18.5 kW
MANUAL NO. TOEP C710606 15C
Type: CIMR-VC
To properly use the product, read this manual thoroughly
and retain for easy reference, inspection, and maintenance.
Ensure the end user receives this manual.
1
2
3
4
5
6
7
8

Questions and Answers

  • R
    Ross Edwards MDSep 12, 2025
    How to fix YASKAWA Controller Er-04?
    • R
      Ricardo WhiteSep 12, 2025
      To fix the YASKAWA Controller error Er-04, check the input data, as there might be a resistance fault due to wrong input data. Check the wiring, as Auto tuning might have exceeded the given time frame. Re-enter the data and repeat the Auto-Tuning, as calculated values might be out of range.
  • S
    suareztoddAug 25, 2025
    What to do if YASKAWA CIMR-VC shows Drive Overload?
    • R
      Robert WrightAug 25, 2025
      If the YASKAWA Controller is showing a drive overload, check the load to ensure it is not too heavy. Also, verify that the drive capacity is sufficient for the load. If there's too much torque at low speed, reduce the load or increase the drive size.
  • K
    Kevin ReynoldsAug 25, 2025
    How to troubleshoot YASKAWA CIMR-VC Ground d Fault?
    • E
      Eddie MillerAug 26, 2025
      To troubleshoot a ground fault in your YASKAWA Controller, check the output wiring and motor for short circuits or broken insulation. If the cable or motor insulation is damaged, replace the broken parts. Also, if there's excessive stray capacitance at the drive output, try reducing the carrier frequency.
  • T
    thomas39Sep 23, 2025
    How to resolve YASKAWA Controller l Circuit ult to?
    • A
      Amy RogersSep 23, 2025
      To resolve an l Circuit ult to on the YASKAWA Controller, cycle the drive power supply, as there is a problem in the drive’s control circuit. Initialize the drive. Replace the drive if the fault occurs again.
  • T
    tsteinSep 12, 2025
    How to troubleshoot YASKAWA CIMR-VC Controller oPE02?
    • E
      Erik MaxwellSep 12, 2025
      To troubleshoot the YASKAWA Controller error oPE02, set parameters to the proper values, because parameters were set outside the allowable setting range.
  • J
    jaysmithSep 18, 2025
    What does YASKAWA Controller End2 mean?
    • R
      rebeccahaleSep 18, 2025
      The YASKAWA Controller error End2 means motor iron-core saturation alarm. Check the input data, as calculated core saturation values might be out of range. Check the motor wiring, because incorrect data was entered. Perform Auto-Tuning without load connected.
  • L
    Lisa AtkinsonSep 5, 2025
    What to do if YASKAWA CIMR-VC Controller shows Externa l Faults to ?
    • A
      Ann TaylorSep 5, 2025
      If your YASKAWA Controller is showing external faults, find out why the device tripped the EF, remove the cause and reset the fault, as an external fault was triggered by an external device via one of the digital inputs S1 to S6. Also, check the functions assigned to the digital inputs, as the digital inputs might be set up incorrectly.
  • S
    Steven ValenzuelaSep 6, 2025
    How to troubleshoot YASKAWA CIMR-VC Controller Undervoltage?
    • C
      Charles WilliamsSep 6, 2025
      If your YASKAWA Controller displays a Controller Undervoltage error, cycle power to the drive. If the fault continues to occur, replace the drive.
  • J
    Justin HamptonSep 18, 2025
    How to resolve YASKAWA Controller End3?
    • L
      Laura MillerSep 22, 2025
      To resolve the YASKAWA Controller error End3, check the input data and repeat tuning, because it indicates a rated current alarm.
  • B
    boyleandreaAug 30, 2025
    What causes YASKAWA CIMR-VC Safe D Fa isable ult ?
    • R
      Rebecca Nash DVMAug 30, 2025
      The YASKAWA Controller Safe Disable fault occurs when the drive output is disabled while only one of the Safe Disable inputs is open. Check the wiring from the upper controller and make sure that both signals are set correctly by the controller. If the signals are correctly set and the alarm persists, consider replacing the drive.