7.4 Fault
266 YASKAWA SIEPC71061753C GA500 Technical Manual
Code Name Causes Possible Solutions
oFA03
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA04
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA05
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA06
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. Re-energize the drive. If the problem continues, replace the
option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA10
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA11
Option Card Error Occurred at
Option Port CN5
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA12
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA13
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.
Code Name Causes Possible Solutions
oFA14
Option Card Connection Error
(CN5)
A fault occurred in the option card. 1. De-energize the drive.
2. Make sure that the option card is correctly connected to the
connector.
3. If the problem continues, replace the option card.
Note:
Do a Fault Reset to clear the fault.