EasyManua.ls Logo

YASKAWA GA50C4004ABA - Page 33

YASKAWA GA50C4004ABA
794 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Mechanical Installation
2
2.3 Installation Position and Clearances
YASKAWA SIEPC71061753C GA500 Technical Manual 33
A - Airflow direction
Figure 2.3 Airflow Direction of Horizontal installation
A - 50 mm (2 in) minimum
B - 30 mm (1.18 in) minimum on each side
C - 100 mm (3.94 in) minimum below
D - Airflow direction
E - External cooling fan
F - 30 mm (1.18 in) between the drive and the
external cooling fan
G - 120 mm (4.72 in) minimum between the external
cooling fan and the enclosure panel
H - Heatsink height
Figure 2.4 Installation Clearances for Horizontal Installation: B001 - B012, 2001 - 2021, and 4001 - 4012
A - 50 mm (2 in) minimum
B - 30 mm (1.18 in) minimum on each side
C - 100 mm (3.94 in) minimum above and below
D - Airflow direction
Figure 2.5 Installation Clearances for Horizontal Installation: B018, 2030 - 2082, and 4018 - 4060

Table of Contents

Other manuals for YASKAWA GA50C4004ABA

Related product manuals