Preface and General Precautions
1
1.2 Applicable Documentation
YASKAWA TOEPC71061779E GA800 DRIVE INSTALLATION MANUAL
7
1.2 Applicable Documentation
Document Description
GA800 Series
IP55/UL Type 12 Heatsink External Mounting
Installation Manual
Read this manual before you install this drive.
This manual gives information about how to install the IP55/UL Type 12 Heatsink External Mounting drive.
GA800 Series
AC Drive for Industrial Applications
Installation & Primary Operation
For information about drive settings, refer to the manuals.
The manuals provide information about basic installation, wiring, operation procedures, functions, troubleshooting, and
maintenance.
The manuals also include important information about parameter settings and tuning the drive.
You can download drive manuals from the Yaskawa product and technical information website shown on the back cover of this
manual.
GA800 Series
AC Drive for Industrial Applications
Technical Reference

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA GA800 GA80U Series and is the answer not in the manual?

YASKAWA GA800 GA80U Series Specifications

General IconGeneral
SeriesGA800 GA80U Series
Output VoltageMatches Input Voltage
Power Range0.4kW to 1.5MW
Power Rating0.4 kW to 450 kW
Control MethodV/f control
Overload Capacity150% for 60 seconds
Cooling MethodAir Cooled
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overheat, Short circuit
CommunicationEthernet, Modbus, DeviceNet, Profibus, CC-Link
SafetySTO (Safe Torque Off)
Operating Temperature+50°C
Humidity5% to 95% (non-condensing)
Enclosure RatingIP20, IP00