V1000 to GA500
Industrial AC Microdrive
Product Transition Guide
Model: CIMR-VU
This guide lists only comparable models. Refer to the GA500 Selection Guide
No. SL.GA500.01 for a list of all available models.
Catalog Code: GA50U
240 V Single-Phase Input : 1/6 to 5 HP
240 V Three-Phase Input : 1/6 to 30 HP
480 V Three-Phase Input : 1/2 to 40 HP
240 V Single-Phase Input : 1/8 to 5 HP
240 V Three-Phase Input : 1/8 to 25 HP
480 V Three-Phase Input : 1/2 to 25 HP

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the YASKAWA GA50U4004ABA and is the answer not in the manual?

YASKAWA GA50U4004ABA Specifications

General IconGeneral
BrandYASKAWA
ModelGA50U4004ABA
CategoryDC Drives
LanguageEnglish

Summary

Model Identification

Identify Your Model

Compares catalog numbers to understand nameplate and code differences between drive series.

Replacement GA500 Drive Selection

Table 1 Single-Phase 240 V Models

Cross-references V1000 single-phase 240V models to GA500 models.

Table 2 Three-Phase 240 V Models

Cross-references V1000 three-phase 240V models to GA500 models.

Table 3 Three-Phase 480 V Models

Cross-references V1000 three-phase 480V models to GA500 models.

Dimensions and Adapters

Dimension Comparison and Mounting Kits

Compares physical dimensions and mounting for V1000 and GA500 drives.

Branch Circuit Protection

V1000 Branch Circuit Protection

Details fuse types, ratings, and ampacity for V1000 branch circuit protection.

GA500 Branch Circuit Protection

Recommends semiconductor fuses for GA500 branch circuit protection.

Main Circuit and Motor Wiring

Main Circuit Connection Diagram

Illustrates the typical main circuit connection for AC drives.

Main Circuit Wiring Procedure

Outlines the steps for wiring main circuit terminals correctly.

Wire Termination Differences V1000 to GA500

Highlights differences in wire termination methods between V1000 and GA500.

Main Circuit and Motor Terminal Layout Comparison

Compares the physical layout of main circuit and motor terminals.

Main Circuit and Motor Wire Gauge and Tightening Torque

Provides recommended wire gauges and tightening torques for drive terminals.

Control Circuit Wiring

Control Circuit Terminal Layout

Shows the layout of control circuit terminals for V1000 and GA500 drives.

Control Circuit Connection Diagrams

Illustrates V1000 and GA500 control circuit wiring connections.

Control Circuit I/O Cross Reference

Compares digital and analog I/O functions and signal levels between V1000 and GA500.

Control Circuit Switches and Jumpers

Details the settings for DIP switches and jumpers on V1000 and GA500 drives.

Transfer of Parameter Settings

Transfer Parameters via DriveWizard Industrial PC Software

Explains using PC software for transferring V1000 parameters to GA500.

About DriveWizard Mobile for Android and iOS

Discusses the mobile app for managing GA500 drive settings.

Procedure - Manual Transfer of V1000 Parameters to the GA500 using the Keypad

Provides a step-by-step guide for manually transferring V1000 parameters.

Parameters with Default Value or Setting Range Differences

Lists parameters with differing setting ranges or default values between V1000 and GA500.

Carrier Frequency - C6-02 [Carrier Frequency Selection]

Watt Loss Comparison

Single-Phase 240 V Models, Watt Loss Comparison

Compares watt loss between V1000 and GA500 single-phase 240V models.

Three-Phase 240 V Models, Watt Loss Comparison

Compares watt loss between V1000 and GA500 three-phase 240V models.

Three-Phase 480 V Models, Watt Loss Comparison

Compares watt loss between V1000 and GA500 three-phase 480V models.

Network Communication and Control I/O Options

Other Option Compatibility