5
5.1 Common Drive Specifications
YASKAWA TOEPC71061779E GA800 DRIVE INSTALLATION MANUAL
85
Item
Specification
Humidity
95% RH or less
Do not let condensation form on the drive.
Storage Temperature
-20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Surrounding Area
Pollution degree 2 or less
Install the drive in an area without:
• Oil mist, corrosive or flammable gas, or dust
• Metal powder, oil, water, or other unwanted materials
• Radioactive materials or flammable materials, including wood
• Harmful gas or fluids
• Salt
• Direct sunlight
Altitude
1000 m (3281 ft) maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
• Installing the drive at 2000 m (6562 ft) or lower
• Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative when not grounding the neutral point.
Vibration
• 10 Hz to 20 Hz: 1 G (9.8 m/s
2
, 32.15 ft/s
2
)
• 20 Hz to 55 Hz:
2004 to 2211, 4002 to 4168, T103 to T168: 0.6 G (5.9 m/s
2
, 19.36 ft/s
2
)
2257 to 2415, 4208 to 4720, 5125 to 5472, T208 to T720: 0.2 G (2.0 m/s
2
, 6.56 ft/s
2
)
Installation
Orientation
Install the drive vertically for sufficient airflow to cool the drive.
Table 5.4 Standard
Item Specification
Standard
Three-Phase 200 V class and 400 V class, and 6-Phase/12-Pulse 400 V class:
• UL 508C
• EN61800-3
• IEC/EN61800-5-1
• Two Safe Disable inputs and one EDM output according to EN ISO 13849-1:2015 (PL e (Cat.3)), IEC/EN61508 SIL3
Three-Phase 600 V class:
• UL 508C
Protection Design
IP00/IP20/UL Open Type
IP20/UL Type 1
IP55/UL Type 12 Heatsink External Mounting
Note: