Specifications
5
5.1 Common Drive Specifications
YASKAWA TOEPC71061779E GA800 DRIVE INSTALLATION MANUAL
85
Item
Specification
Humidity
95% RH or less
Do not let condensation form on the drive.
Storage Temperature
-20 °C to +70 °C (-4 °F to +158 °F) (short-term temperature during transportation)
Surrounding Area
Pollution degree 2 or less
Install the drive in an area without:
Oil mist, corrosive or flammable gas, or dust
Metal powder, oil, water, or other unwanted materials
Radioactive materials or flammable materials, including wood
Harmful gas or fluids
Salt
Direct sunlight
Altitude
1000 m (3281 ft) maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
Installing the drive at 2000 m (6562 ft) or lower
Installing the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and grounding the neutral point on the power supply.
Contact Yaskawa or your nearest sales representative when not grounding the neutral point.
Vibration
10 Hz to 20 Hz: 1 G (9.8 m/s
2
, 32.15 ft/s
2
)
20 Hz to 55 Hz:
2004 to 2211, 4002 to 4168, T103 to T168: 0.6 G (5.9 m/s
2
, 19.36 ft/s
2
)
2257 to 2415, 4208 to 4720, 5125 to 5472, T208 to T720: 0.2 G (2.0 m/s
2
, 6.56 ft/s
2
)
Installation
Orientation
Install the drive vertically for sufficient airflow to cool the drive.
Table 5.4 Standard
Item Specification
Standard
Three-Phase 200 V class and 400 V class, and 6-Phase/12-Pulse 400 V class:
UL 508C
EN61800-3
IEC/EN61800-5-1
Two Safe Disable inputs and one EDM output according to EN ISO 13849-1:2015 (PL e (Cat.3)), IEC/EN61508 SIL3
Three-Phase 600 V class:
UL 508C
Protection Design
IP00/IP20/UL Open Type
IP20/UL Type 1
IP55/UL Type 12 Heatsink External Mounting
Note:
To change an IP00/IP20/UL Open Type drive to an IP20/UL Type 1 drive, install a UL Type 1 kit.