GPD315 Modbus RTU Technical Manual TM 4325
Page
11
Normal Response Message
Table 4-3 Read Normal Response Message
Slave Address 02h
Function Code 03h
Number of Data Bytes 08h
Upper 17h
Starting Register
Lower 70h
Upper 17h
Next Register
Lower 70h
Upper 01h
Next Register
Lower 09h
Upper 00h
Last Register
Lower 00h
Lower 38h
CRC-16
Upper ACh
The normal response message contains the same slave address and function code as the
command message, indicating to the master which slave is responding and to what type of
function it is responding.
The number of data bytes is the number of data bytes returned in the response message. The
number of data bytes is actually the quantity (in the command message) times 2, since there are
two bytes of data in each register.
The data section of the response message contains 8 upper and 8 lower bits of data for each
register that has been read from the drive.
A CRC-16 value is generated from a calculation using the values of the address, function code,
number of data bytes, and register data sections of the message. The procedure for calculating
a CRC-16 value is described at the end of this chapter. When the master receives the response
message it calculates a CRC-16 value and compares it to the one in the CRC-16 field of the
response message. If these two CRC-16 values are the same the master has received the
proper response message.