GPD315/V7 Modbus RTU Technical Manual TM 4325
Page
36
Set up for Serial Communication Control
The first table indicates the functions or commands that can be accessed via serial
communication, external terminals, or the digital operator when the drive’s parameter n003 is set
up for serial communication (n003 = 3). The “O” indicates that the function is Operable from that
source, and “n/a” indicates that the function is not available from that source.
Table 7-1: Set up for Serial Communication Control
From
Data
Code
Bit
No.
Data Description
Function
Availability
0 Run Command O
1 Forward / Reverse O
2 External Fault O
3 Fault Reset O (1)
4 Multi-function Input Reference 1 O
5 Multi-function Input Reference 2 O
6 Multi-function Input Reference 3 O
7 Multi-function Input Reference 4 O
8 Multi-function Input Reference 5 O
9 Multi-function Input Reference 6 O
001h
A Multi-function Input Reference 7 O
003h- unused -
008h
0 Multi-function Output - Contact O (2)
1 Multi-function Output Photo coupler 1 O (3)
2 Multi-function Output Photo coupler 2 O (4)
SERIAL
COMM.
009h
3-7 unused -
Forward Run (2 wire); Run Command (3 wire) n/a
Reverse Run (2 wire); Stop Command (3 wire) n/a
Multi-function input terminal S3 (5)
Multi-function input terminal S4 (5)
Multi-function input terminal S5 (5)
Multi-function input terminal S6 (5)
EXTERNAL
TERMINALS
Multi-function input terminal S7 (5)
Run Command n/a
Stop Command O (6)
Fault Reset O (1)
DIGITAL
OPERATOR
Local / Remote O (1)
Notes:
1. Effective when run command received from PLC is 0” while in stopped condition.
2. Effective when n057 is “18”.
3. Effective when n058 is “18”.
4. Effective when n059 is “18”.
5. The availability of the multi-function input terminals vary depending upon the settings of
n052, n053, n054, n055, and n056 (the multi-function input settings). See technical
manual TM 4315.
6. Effective only when n007 is “0”.