2.1  Parameter Mode
2-3
∗ When the setting is modified, the parameters whose modified setting is validated only after 
setting validation, the warning A.941 “Change of Parameters Requires the Setting Valida-
tion” is displayed. Turn the power OFF then ON to clear the warning and validate the new 
setting.
4
Press the
 Key to move the cur-
sor to the setting side (to the position of 
the first digit of Pn000.0).
5
Press the
 Key once to set “1” 
for the first digit of Pn.000.0. 
6
Press the
 Key.
The new setting of Pn000 is written to 
the SERVOPACK. The cursor moves to 
the parameter number side and the 
warning A.941 is displayed.
7 To enable the change in the setting, turn the power OFF and ON again.*
Step Display after Operation Keys Operation
BB
− PRM/MON−
Pn000=n.0000
Un002=0 00000
Un008=0 0000000000
Un00D=0 0000000000
BB
− PRM/MON−
Pn000=n.0001
Un002=0 00000
Un008=0 0000000000
Un00D=0 0000000000
A.941
− PRM/MON−
Pn000=n.0001
Un002=0 00000
Un008=0 0000000000
Un00D=0 0000000000