3 Utility Function Mode
3.2.21 Display of SERVOPACK and Servomotor ID (Fn01E)
3-50
(2) Operating Procedure
Use the following procedure.
Step Display after Operation Keys Operation
1
Press the Key to view the main
menu for the utility function mode.
Use the
or Key to move
through the list and select Fn01E.
2
Press the
Key.
The display changes to the Fn01E execu-
tion display.
The SERVOPACK ID information is dis-
played. Use the or Key to
scroll left and right and to view other infor-
mation.
3
Press the
Key.
The servomotor ID information is dis-
played. Use the or Key to
scroll left and right and to view other infor-
mation.
4
Press the
Key.
The encoder ID information is displayed.
Use the or Key to scroll left
and right and to view other information.
5
Press the Key.
The display returns to the main menu of the
utility function mode.
RUN − FUNCTION−
Fn01B:Viblvl Init
Fn01E:SvMotOp ID
Fn01F:FBOpMot ID
Fn020:S− Orig Set
BB − SvMotOp ID−
Driver
SGDV− R70A01A
D00241234590001
02. 04 200V, 50W
Serial number
Manufacturing date
SERVOPACK model
Input voltage
Capacity
BB − SvMotOp ID−
Motor
SGMAV− A5A3A21
D00245789090001
07. 04 200V, 50W
Serial number
Servomotor model
Manufacturing date
Input voltage
Capacity
Encoder resolution
Encoder type
BB ޓ − SvMotOp ID−
Encoder
UTVIH− B20EA
K247− 0225E00200
07. 04 20bit− ABS
Encoder model
Serial number
Manufacturing date
RUN − FUNCTION−
Fn01B:Viblvl Init
Fn01E:SvMotOp ID
Fn01F:FBOpMot ID
Fn020:S− Orig Set