6 Maintenance
6.3 Weld Ground Brush Replacement – Type I
6-2
162068-1CD
162068-1CD
MH-SERIES
POSITIONER
6.3 Weld Ground Brush Replacement – Type I
6.3.1 MH95/185/505/1605
To replace the grounding brush(s) proceed as follows:
1. Shut down cell using main disconnect.
2. Use a flathead screwdriver to disconnect the brush cable(s) from the
ground post (Figure 6-1).
Fig. 6-1: Brush Cable Removal
3. Release the spring tensioner on the back of the brush by squeezing
both black spring levers and pulling away from the faceplate.
4. Reach in and steady the brush case with one hand.
GROUND POST
GROUND BRUSH
CABLE