9.2 List of Parameters
9.2.2 List of Parameters
9-36
Pn631
2
Input Signal Selections
11
0000h to
FFFFh
8543h All
After
restart
Setup
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.X
/SEL0 (Program Step Selection Input 0) Signal Allocation Reference
0 Active when CN1-40 input signal is ON (closed).
page 6-3
1 Active when CN1-41 input signal is ON (closed).
2 Active when CN1-42 input signal is ON (closed).
3 Active when CN1-43 input signal is ON (closed).
4 Active when CN1-44 input signal is ON (closed).
5 Active when CN1-45 input signal is ON (closed).
6 Active when CN1-46 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-40 input signal is OFF (open).
A Active when CN1-41 input signal is OFF (open).
B Active when CN1-42 input signal is OFF (open).
C Active when CN1-43 input signal is OFF (open).
D Active when CN1-44 input signal is OFF (open).
E Active when CN1-45 input signal is OFF (open).
F Active when CN1-46 input signal is OFF (open).
n.X
/SEL1 (Program Step Selection Input 1) Signal Allocation Reference
0 to F
The settings are the same as for /SEL0 (Program Step Selection
Input 0) Signal Allocation.
page 6-3
n.X
/SEL2 (Program Step Selection Input 2) Signal Allocation Reference
0 to F
The settings are the same as for /SEL0 (Program Step Selection
Input 0) Signal Allocation.
page 6-3
n.X
/SEL3 (Program Step Selection Input 3) Signal Allocation Reference
0 to F
The settings are the same as for /SEL0 (Program Step Selection
Input 0) Signal Allocation.
page 6-3