APPENDIX 5 LIST OF ALARM CODES (Cent’d)
Code
Causes
179
OVER TEMP
PANEL INSIDE TEMPERATURE TOO HIGH.
180 SEQ ERROR
SEQUENCE ERROR(1)
181
182
183
184
185
186
187
188
I 89
190
HDLC SYSTEM SO=T ERROR
TRANSMISSION SYS7EM SO F”TWARE ERROR
Code Causes
191
HDLCSOFT CO MM AND ERROR
NC SIDE RECEIVED 5ATA OTHER THAN
TRANSMISSION PROTOCOL BETWEEN AC GC AND
NC.
192 HDLC8530 SEND ERROR
TRANSMISSION NC SEND-SIDE HARDWARE
ERROR.
193
HDLC8530 ERROR
TRANSMISSION NC RECEIVE-SIDE HARDWARE
ERROR,
194
HDLC NAK ERROR 110 TIMES)
SAME DATA IS SENT 10 TIMES IN TRANSMISSION
FROM NC TO ACGC WITHOUT SUCCESS
195 HDLC CMOS FILE ERROR
CMOS FILE READ OR WRITE REQUEST FROM ACGC
TO NC IS NOT EXECUTED,
.—
196 HDLC 1/0 DATA ERROR
SYSTEM VARIABLE READING FROM ACGCTO NC
IS NOT EXECUTED.
.
197
HDLCNC REQUEST ERROR
OPERATION REQUEST COMMAND FROM ACGCTO
NC IS WRONG.
198
HDLC OPERATION ERROR
DATA TRANSFER FROM ACGCTO NC IS DELAYED
MORE THAN 1 MINUTE DURING AC GC OPERATION.
199 AM GCCOMMUN ICATION SYSTEM ERROR
COMMUNICATION ERROR BETWEEN AM GC AND
.,,-
IU L
200 ACGC2 COMMUNICATION SYSTEM ERROR
COMMUNICATION ERROR BETWEEN AC GC120
AND NC.
201
OT (x)
OVER TRAVEL X.
202
OT (Z)
OVER TRAVEL Z.