EasyManua.ls Logo

YOKOGAWA DP harp EJX Series - External Indicator Connection; Communicator Connection; Check Meter Connection

YOKOGAWA DP harp EJX Series
63 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
<6. Wiring>
6-2
IM 01C25B01-01E
Power supply
+
Transmitter terminal box
F0601.ai
Load resistance is not
necessary for 1 to 5 V output.
Figure 6.2 Power Supply Wiring Connection
6.3.2 External Indicator Connection
Available only for 4 to 20mA output type and when
/ALisnotspecied.
Connect wiring for external indicators to the CHECK
(+) and SUPPLY – terminals.
(Note)Useaexternalindicatorwhoseinternalresistanceis10Ω
or less.
Transmitter terminal box
External indicator
F0602.ai
Power supply
+
Figure 6.3 External Indicator Connection
6.3.3 Communicator Connection
■ 4to20mAoutput,BRAIN/HART
IMPORTANT
Analog output may change temporally in
connecting with BRAIN terminal due to an initial
currentowedtoit.Topreventcommunication
signala󰀨ectingtheuppersystem,itis
recommendedtoinstallalow-passlter
(approximately 0.1s)
Connect the BT200 or HART Communicator to the
SUPPLY + and – terminals. (Use hooks.)
Transmitter terminal box
BT200
F0603.ai
Power supply
+
Ignore the polarity since the
BT200 is AC-coupled to the
terminal box.
Figure 6.4 BT200 Connection
■ 1to5Voutput,HART
Connect the HART communicator or
congurationtooltotheSUPPLY-andVOUT
(+) terminals. (Use hooks.)
Transmitter terminal box
F0615.ai
Voltmeter
+
Power supply
+
USB
FieldMate Modem
PC/FieldMate
Figure 6.5 Four wire connection
Transmitter terminal box
F0616.ai
Power supply
+
Voltmeter
+
USB
FieldMate Modem
PC/FieldMate
Figure 6.6 Three wire connection
6.3.4 Check Meter Connection
Available only for 4 to 20mA output type and when
/ALisnotspecied.
Connect the check meter to the CHECK (+) and
SUPPLY – terminals. (Use hooks.)
A 4 to 20 mA DC output signal from the CHECK
(+) and SUPPLY – terminals.
(Note)Useacheckmeterwhoseinternalresistanceis10Ωor
less.
Transmitter terminal box
F0604.ai
Power supply
+
Check meter
Figure 6.7 Check Meter Connection

Table of Contents