TABLE 9: SIDE SUPPLY AIR BLOWER PERFORMANCE - 208/230 VOLTS
1
MODEL #
DNZ
MODE
(COOLING / HEATING)
CFM
EXTERNAL STATIC PRESSURE - IWG
.20 .30 .40 .50 .60 .70 .80 .90 1.0
WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS WATTS
024
HEATING (2 TUBE)
(FACTORY SETTING)
1000 277 292 316 357 399 430 454 ~ ~
024
HEATING (3 TUBE)
(FACTORY SETTING)
1150 362 400 435 473 511 544 578 ~ ~
024
COOLING
(FACTORY SETTING)
800 161 190 218 243 268 297 326 ~ ~
024
COOLING
(FIELD SETTING)
1000 277 292 316 357 399 430 454 ~ ~
030
COOLING
(FACTORY SETTING)
1000 248 298 325 365 385 411 470 498 500
030
COOLING
(FIELD SETTING)
1250 342 385 431 474 510 562 614 657 694
030
HEATING (2 TUBE)
(FACTORY SETTING)
850 169 217 237 278 302 334 374 401 431
030
HEATING (3 TUBE)
(FACTORY SETTING)
1100 300 338 378 416 447 493 539 576 609
036
COOLING
(FACTORY SETTING)
1200 354 396 436 511 548 599 641 677 721
036
COOLING
(FIELD SETTING)
1350 442 503 563 606 648 685 721 774 826
036
HEATING (2 TUBE)
(FACTORY SETTING)
700 207 231 254 298 320 349 ~ ~ ~
036
HEATING (3 TUBE)
(FACTORY SETTING)
1250 383 432 478 543 581 628 ~ ~ ~
036
HEATING (4 TUBE)
(FACTORY SETTING)
1350 442 503 563 606 648 685 ~ ~ ~
042
COOLING
(FACTORY SETTING)
1150 348 388 428 489 549 584 620 663 705
042
COOLING
(FIELD SETTING)
1400 418 465 514 596 678 742 772 811 873
042
HEATING (3 TUBE)
(FACTORY SETTING)
1500 450 500 553 641 729 798 830 872 939
042
HEATING (4 TUBE)
(FACTORY SETTING)
1275 388 433 478 545 612 652 691 739 787
048
COOLING
(FACTORY SETTING)
1400 427 476 525 599 673 716 759 812 865
048
COOLING
(FIELD SETTING)
1600 476 532 587 687 786 872 958 994 1030
048
HEATING (3 TUBE)
(FACTORY SETTING)
1525 458 511 564 654 744 814 ~ ~ ~
048
HEATING (4 TUBE)
(FACTORY SETTING)
1600 476 532 587 687 786 872 ~ ~ ~
048
HEATING (5 TUBE)
(FACTORY SETTING)
1600 476 532 587 687 786 872 ~ ~ ~
060
HEATING (3 TUBE)
(FACTORY SETTING)
1500 297 348 400 470 540 610 680 750 820
060
HEATING (4 & 5 TUBE)
(FACTORY SETTING)
1700 443 497 550 620 690 760 830 900 ~
060
COOLING
(FACTORY SETTING)
1800 515 570 625 690 755 820 962 ~ ~
060
COOLING
(FIELD SETTING)
2000 700 760 820 928 ~ ~ ~ ~ ~
1.
Above data includes allowances for a dry coil, gas heat exchanger and no filters. For additional pressure drops, refer to Tables 11
and 12.