EasyManua.ls Logo

York DNP024 - Ratings Cooling;Gas Heating

York DNP024
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
036-21366-007-A-1205
Unitary Products Group 7
TABLE 2: RATINGS COOLING/GAS HEATING
MODEL
DNP
NET COOLING CAPACITY
1
SOUND
RATING
(dbels)
2
GAS HEAT CAPACITY / EFFICIENCIES
MBH
SEER
3
EER
4
INPUT
(MBH)
OUTPUT
(MBH)
AFUE
5
(%)
NUMBER OF
BURNERS
TEMP.
RISE
(°F) RANGE
024N03606 25.4 13.3 11.6 81 45 36 80.2 2 25 - 55
024N05606 25.4 13.3 11.6 81 70 56 80.2 3 30 - 60
030N03606 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55
030N03625 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55
030N03646 30.6 13.4 11.75 80 45 36 80.2 2 25 - 55
030N05606 30.6 13.4 11.75 80 70 56 80.2 3 30 - 60
030N05625 30.6 13.4 11.75 80 70 56 80.2 3 30 - 60
030N05646 30.6 13.4 11.75 80 70 56 80.2 3 30 - 60
036N03606 37.4 13.65 11.75 81 45 36 80.4 2 25 - 55
036N03625 37.4 13.65 11.75 81 45 36 80.4 2 25 - 55
036N03646 37.4 13.65 11.75 81 45 36 80.4 2 25 - 55
036N03658 37.4 13.65 11.75 81 45 36 80.4 2 25 - 55
036N05606 37.4 13.65 11.75 81 70 56 80.2 3 25 - 55
036N05625 37.4 13.65 11.75 81 70 56 80.2 3 25 - 55
036N05646 37.4 13.65 11.75 81 70 56 80.2 3 25 - 55
036N05658 37.4 13.65 11.75 81 70 56 80.2 3 25 - 55
036N07206 37.4 13.65 11.75 81 90 72 80.1 4 30 - 60
036N07225 37.4 13.65 11.75 81 90 72 80.1 4 30 - 60
036N07246 37.4 13.65 11.75 81 90 72 80.1 4 30 - 60
036N07258 37.4 13.65 11.75 81 90 72 80.1 4 30 - 60
042N06506 44 13.7 10.65 80 80 64 80.6 3 25 - 55
042N06525 44 13.7 10.65 80 80 64 80.6 3 25 - 55
042N06546 44 13.7 10.65 80 80 64 80.6 3 25 - 55
042N06558 44 13.7 10.65 80 80 64 80.6 3 25 - 55
042N09006 44 13.7 10.65 80 108 86 80.8 4 45 - 75
042N09025 44 13.7 10.65 80 108 86 80.8 4 45 - 75
042N09046 44 13.7 10.65 80 108 86 80.8 4 45 - 75
042N09058 44 13.7 10.65 80 108 86 80.8 4 45 - 75
048N06506 48 13.2 11.7 84 80 64 80.8 3 25 - 55
048N06525 48 13.2 11.7 84 80 64 80.8 3 25 - 55
048N06546 48 13.2 11.7 84 80 64 80.8 3 25 - 55
048N06558 48 13.2 11.7 84 80 64 80.8 3 25 - 55
048N09006 48 13.2 11.7 84 108 86 80.6 4 35 - 65
048N09025 48 13.2 11.7 84 108 86 80.6 4 35 - 65
048N09046 48 13.2 11.7 84 108 86 80.6 4 35 - 65
048N09058 48 13.2 11.7 84 108 86 80.6 4 35 - 65
048N11006 48 13.2 11.7 84 135 107 80.5 5 45 - 75
048N11025 48 13.2 11.7 84 135 107 80.5 5 45 - 75
048N11046 48 13.2 11.7 84 135 107 80.5 5 45 - 75
048N11058 48 13.2 11.7 84 135 107 80.5 5 45 - 75
060N06506 55.5 13.0 11.2 84 80 64 80.8 3 25 - 55
060N06525 55.5 13.0 11.2 84 80 64 80.8 3 25 - 55
060N06546 55.5 13.0 11.2 84 80 64 80.8 3 25 - 55
060N06558 55.5 13.0 11.2 84 80 64 80.8 3 25 - 55
060N09006 55.5 13.0 11.2 84 108 86 80.6 4 35 - 65
060N09025 55.5 13.0 11.2 84 108 86 80.6 4 35 - 65
060N09046 55.5 13.0 11.2 84 108 86 80.6 4 35 - 65
060N09058 55.5 13.0 11.2 84 108 86 80.6 4 35 - 65
060N11006 55.5 13.0 11.2 84 135 107 80.5 5 45 - 75
060N11025 55.5 13.0 11.2 84 135 107 80.5 5 45 - 75
060N11046 55.5 13.0 11.2 84 135 107 80.5 5 45 - 75
060N11058 55.5 13.0 11.2 84 135 107 80.5 5 45 - 75
1.
Net Cooling Capacity = ARI 210 standard rating conditions.
2.
(dbels) = ARI 270-95
3.
Seasonal Energy Efficiency Ratio - the total cooling output in BTU’s during a normal annual usage period for cooling divided by the
total electric power input in watt-hours during the same period.
4.
Tested in accordance with ARI 210 Standard Rating Conditions.
5.
AFUE = Annual Fuel Utilization Efficiency.

Table of Contents