EasyManua.ls Logo

York YS - Table of Contents

York YS
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 JOHNSON CONTROLS
INTRODUCTION ........................................................... 3
RATINGS ....................................................................... 4
OPTIVIEW CONTROL CENTER ................................... 5
MECHANICAL SPECIFICATIONS ................................ 13
ACCESSORIES & MODIFICATIONS ............................ 17
UNIT COMPONENTS ................................................... 19
APPLICATION DATA ..................................................... 20
DIMENSIONS – STD ..................................................... 28
S0-S3 Compressor .................................................... 28
S4 & S5 Compressor ............................................... 29
Compact Water Box Nozzle Arrangements ............... 30
Floor Layout .............................................................. 31
Cooler Nozzle Arrangements .................................... 32
Condenser Nozzle Arrangements ............................. 34
WEIGHTS – STD ........................................................... 36
DIMENSIONS – METRIC .............................................. 38
S0-S3 Compressor .................................................... 38
S4 & S5 Compressor ............................................... 39
Compact Water Box Nozzle Arrangements ............... 40
Floor Layout .............................................................. 41
Cooler Nozzle Arrangements .................................... 42
Condenser Nozzle Arrangements ............................. 44
WEIGHTS – METRIC .................................................... 46
GUIDE SPECIFICATIONS ............................................ 48
METRIC CONVERSION TABLES ................................. 53
NOMENCLATURE
The model number denotes the following characteristics of the unit:
YS BB BA S0 – CF E S
Model
Cooler Code
Design Level
Power Supply:
– for 60 Hz
5 for 50 Hz
Condenser Code
Compressor Code
Motor Code
Special Features
TABLE OF CONTENTS
PAGE
LIST OF TABLES
1 Water Flow Rate Limits.................. 20
2 Motor Voltage Variations ................ 23
3 60 Hz Electrical Data ..................... 25
4 Motor Starters ................................ 25
5 50 Hz Electrical Data ..................... 26
6 Available Compressor/Shell/
Motor Combinations
(R-22 & R-134a) ............................ 26
7 Available Compressor/Shell/
Motor Combinations
(50 Hz, R-134a Only) ..................... 27
PAGE
TABLE
NO.

Related product manuals