PG 6
MENU Screen Functions
Press MENU to bring up MENU screen.
TIME of DAY
Touch the left (down) or right (up) arrows next to the time display to set the current time (1 minute per
touch). Touch and hold the arrow for fast time set (15 minute jumps).
DAY of Week Touch DAY area to select present day.
SWING (HVAC cycling rate) This feature allows you to set the desired variance in temperature
between the CT100 setting and the room temperature required before the heating or cooling system
will turn on—from 0.5° to 2.0° F (.25° to 1° C). For example, if SWING is set to 2.0° F and the CT100
is set to 70°F Target Temperature, the heat cycle will start when room temperature drops to 68°F.
Similarly, the cooling system will start when the room temperature increases to 72°F. The HVAC then
runs and will shut off at the Target Temperature.
To set SWING:
Touch SWING.
Touch the left/right arrows to set the SWING from 0.5° to 2.0°F.
The HVAC will run more frequently at .5°F and less at 2°F. Default is 1°F.
Touch to return to the MENU screen.