1.8. Alarm list
Cod Description Type of restoring
A01 Environment probe failure Manual
A04 Low pressure alarm Automatic
A05 Oil level alarm Display Only
A06 Air fi lter alarm Display Only
A07 Water temperature alarm Manual
A08 Microdoor Automatic
A09 Open door Automatic
A10 Oil pressure alarm Manual
A11 Maximum pressostat alarm Automatic
A12 High temperature alarm Display Only
A13 Low temperature alarm Display Only
A14 Thermal protection Automatic
A15 Low battery level Manual
A16 Start failed Manual
A17 Alternator failure Manual
A18 Pre-heat water probe failure Display Only
1.9. Alarm description
A01 Enviroment probe failure alarm
This alarm causes the machine to stop permanently until the failure is repaired. To re-start the machine, you should
reset the alarm following the procedure described in the above-mentioned paragraph and press the on/off
key.
A04/11 Pressostat alarm
It occurs upon a maximum or minimum pressure detection. The causes for the intervention of the maximum pressure
sensor may be due to inappropriate cleaning of the condenser or slackening of the condenser fan belts, The interven-
tion of the minimum pressure sensor may be due to Freon leakage. The intervention makes the machine stop until
the alarm ends.
A05 Oil level alarm
Is a signal only alarm which does not affect the machine operation.
A06 Air fi lter alarm
Is a signal only alarm which does not affect the machine operation.
A07 Water temperature alarm
Occurs when the radiator water temperature exceeds the allowed value. It causes the diesel motor to stop. To re-start