EasyManuals Logo
Home>ZiLOG>Computer Hardware>eZ80

ZiLOG eZ80 User Manual

Default Icon
411 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
eZ80
®
CPU
User Manual
UM007714-0908 Registers and Bit Flags
15
where:
C = Carry Flag
N = Add/Subtract Flag
P/V = Parity/Overflow Flag
H = Half-Carry Flag
Z = 0 Flag
S = Sign Flag
X = Not used
Each of the two CPU flag registers contain six bits of status information that are set or
reset by CPU operations. Bits 3 and 5 are not used. Four of these bits are testable (C, P/V,
Z and S) for use with conditional
jump
,
call
or
return
instructions. Two flags are not test-
able (H, N) and are used for BCD arithmetic.
Carry Flag (C)
The Carry Flag bit is set or reset, depending on the operation that is performed. For
ADD
instructions that generate a carry and
SUBTRACT
instructions that generate a borrow, the
Carry flag is set to 1. The Carry flag is reset by an
ADD
that does not generate a carry, and
a subtract that does not generate a borrow. This saved carry facilitates software routines
for extended precision arithmetic. Also, the
DAA
instruction sets the Carry flag to 1 if the
conditions for making the decimal adjustment are met.
For the
RLA
,
RRA
,
RLC
and
RRC
instructions, the Carry flag is used as a link between
the least significant bit (lsb) and most significant bit (msb) for any register or memory
location. During the
RLCA
,
RLC m
and
SLA m
instructions, the carry contains the last
value shifted out of bit 7 of any register or memory location. During the
RRCA
,
RRC m
,
SRA m
and
SRL m
instructions, the carry contains the last value shifted out of bit 0 of
any register or memory location. For the logical instructions
AND A s
,
OR A s
, and
XOR
A s
, the carry is reset. The Carry flag can also be set (
SCF
) and complemented (
CCF
).
Add/Subtract Flag (N)
The Add/Subtract (N) flag is used by the decimal adjust accumulator instructions (
DAA
)
to distinguish between
ADD
and
SUBTRACT
instructions. For all
ADD
instructions, N
is set to 0. For all
SUBTRACT
instructions, N is set to 1.
Parity/Overflow Flag (P/V)
The Parity/Overflow (P/V) flag is set or reset, depending on the operation that is per-
formed. For arithmetic operations, this flag indicates an overflow condition when the
result in the accumulator is greater than the maximum possible number (+127) or is less
than the minimum possible number (–128). This overflow condition can be determined by
examining the sign bits of the operands.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ZiLOG eZ80 and is the answer not in the manual?

ZiLOG eZ80 Specifications

General IconGeneral
BrandZiLOG
ModeleZ80
CategoryComputer Hardware
LanguageEnglish

Related product manuals