Page 14 of 16 801525 v3.05 09.20 HT C Com Install Instructions
Commissioning
4.3 - Command-Centre Flush
All G4 HydroTap products are currently sanitised after functional test at the factory. Due to the sanitisation
process, residue from the sanitisation liquid might remain in the product, which requires the products to be
ushed with fresh water at installation.
• Dispense 6 litres of chilled water from the chilled outlet (equivalent of two complete tankfuls of water).
1. Turn the stop cock ON
2. Press [Start] [Stop] buttons to start and stop the filter flush.
3. Allow at least 10 litres of water to flush through the filter.
4. Once the filter flush is finished, Turn the stop cock OFF
then press [Stop] to end filter flush mode.
NOTE: For any subsequent lter changes or any operational procedures, please refer to the HydroTap user
guide, located inside the lter housing access door.