09807042 v1.02 08.22 HydroTap G5 UltraCare Install Instructions
SECTION 4: Technical data
Electricity supply requirements
220-240V 50Hz AC.
A pressure limiting valve must be fitted for mains water pressures
above the maximum limits stated above in accordance with local
plumbing regulations.
Note: All models (excluding UK) have an internal pressure limiting device
to reduce the maximum mains regulated pressure (700kPa in Australia),
protecting the system against pressure surges above 500kPa.
Water supply pressure requirements
Component
Min - Max pressure, kPA (bar)
Australia UK
HydroTap 170 (1.7) - 700 (7.0) 170 (1.7) - 500 (5.0)
Vented Mixer Tap 300 (3.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Booster 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Limescale filter 200 (2.0) - 700 (7.0) 200 (2.0) - 500 (5.0)
Water supply connection
1/2” BSP (G1/2).
Country
Component Australia, NZ UK
Command Centre 1x 220 - 240V AC 10A socket 1x 220 - 240V AC 13A sockets
Booster 1x 220 - 240V AC 10A socket 1x 220 - 240V AC 13A sockets
UV-C module 1x 220 - 240V AC 10A socket 1x 220 - 240V AC 13A sockets