10
❹ Maintenance
4.1 I Winterising
The pump must be fully wintered in the event of a risk of frost or extended electrical
disconnec on. If the pump freezes it may cause severe damage and invalidate the warranty.
To avoid damaging the appliance with condensa on, do not fully cover it.
If the pump is posi oned below the water level, close the isola on valves at suc on and discharge.
Drain the pump (using the 2 bleed screws) and the hydraulic circuit, following the swimming pool manufacturer's
instruc ons.
Remove the 2 bleed screws and keep them to reinstall them when the pump is put back into opera on.
You are recommended to disconnect the electrical power cable then unscrew the hydraulic connectors to store the
pump in a dry place away from frost.
Store the pump in a dry environment at a temperature that varies as li le as possible to prevent condensa on which
would damage the pump.
4.2 I Servicing
It is recommended that the appliance undergo general servicing at least on a yearly basis
to ensure proper opera on, maintain performance levels and poten ally prevent certain
failures. These opera ons are carried out at the user's expense and certain opera ons must
be performed by a technician.
4.2.1 User maintenance
Make sure that the pump and electrical compartment contain no foreign bodies.
Clean the outside of the appliance, do not use solvent-based products.
Clean the pre- fi lter strainer, the cover and the gasket regularly.
Check that the pre- fi lter strainer is correctly in place, or it may prevent the cover from closing fully.
4.2.2 Maintenance to be carried out by a qualifi ed technician
Check the connec on of the metal masses to the earth.
Check that the electrical cables are correctly  ghtened and connected and that the switch box is clean.
Check that the user interface is correctly connected.