❷ Installa on
2.1 I Selec ng the loca on
The pump must be installed:
- before the fi lter, a hea ng and/or water treatment system,
- at a minimum distance of 3.5 metres from the edge of the pool, to avoid any water being sprayed onto the
appliance. Some standards allow for other distances. Refer to the regula ons in eff ect in the country of installa on.
- ideally 30 cm below the water level,
- out of an area subject to fl ooding, or on a base with drainage,
- in a ven lated area to allow the pump and motor to cool.
The pump must not be installed:
- in an area subject to splashing or rain.
- more than 1 m above the water level.
- near a heat source or source of fl ammable gas.
- in an area that cannot be cleaned or kept free of leaves, dry foliage, and other poten ally fl ammable items.
Easy access is required for maintenance work on the appliance.
Place on a stable, level and solid surface (e.g. concrete fl oor).
If necessary, use the bases (2 types of base, not supplied, available as an op on) to raise the pump to the level of the
exis ng pipes.
Anchor the pump to the ground using the adapted founda on bolt.