5
❷ Installa on
2.1 I Selec ng the loca on
• The pump must be installed:
- before the fi lter, a hea ng and/or water treatment system,
- at a minimum distance of 3.5 metres from the edge of the pool, to avoid any water being sprayed onto the
appliance. Some standards allow for other distances. Refer to the regula ons in eff ect in the country of installa on.
- ideally 30 cm below the water level,
- out of an area subject to fl ooding, or on a base with drainage,
- in a ven lated area to allow the pump and motor to cool.
• The pump must not be installed:
- in an area subject to splashing or rain.
- more than 1 m above the water level.
- near a heat source or source of fl ammable gas.
- in an area that cannot be cleaned or kept free of leaves, dry foliage, and other poten ally fl ammable items.
• Easy access is required for maintenance work on the appliance.
• Place on a stable, level and solid surface (e.g. concrete fl oor).
• If necessary, use the bases (2 types of base, not supplied, available as an op on) to raise the pump to the level of the
exis ng pipes.
• Anchor the pump to the ground using the adapted founda on bolt.
EN