❺ Troubleshoo ng
If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
If the problem con nues, contact your retailer.
: Ac ons to be performed by a qualifi ed technician only
5.1 I Appliance behaviour
The pump does not start
/ the motor does not
turn.
Filtra on outside of a scheduled opera ng range (“Auto” mode). Check the ltra on
clock se ngs.
Faulty user interface fuse, replace.
Electric power cut. Check the circuit breaker(s).
Check the connec on between the power cable and the motor terminals.
Check that the user interface cable is not damaged.
The "error" light fl ashes, see § “5.2 I Error codes”
Check that the motor sha rotates freely. Check that there is no debris in the pre- fi lter
strainer.
If debris remains, remove the pump to access the turbine.
The pump doesn’t prime
/ air can be seen in the
pre- fi lter strainer.
Check the posi on of all valves in the hydraulic circuit.
Air is stuck in the circuit, drain the hydraulic circuit (drain screw on the fi lter).
The pool’s water level is too low, air is being sucked into the circuit, fi ll the pool.
The gasket of the pre- lter strainer lid is defec ve, check the condi on of the gasket
and the correct air- ghtness of the lid.
Low fl ow rate / low fi lter
pressure
Pre- fi lter basked full of debris: clean.
Air leak in the circuit. Check all  ghtening torques.
The turbine and the pump diff user are blocked or worn, replace.
The diff user seal is worn, replace.
Low fl ow rate / high fi lter
pressure
The fi lter is clogged. Wash the fi lter (or the cartridge depending on the case).
Check the posi on of all valves in the hydraulic circuit.
Pump making a lot of
noise
Air leak or cavita on in the suc on piping. Check the posi on of the valves and adjust
where necessary.
Pump incorrectly posi oned on the ground. Check that it is res ng in a fl at posi on on
a hard, horizontal ground. Use an -vibra on studs where necessary.
A foreign body is present in the pre- fi lter strainer.
A foreign body is present in the pump body (in this case, the pump must be
removed).
Leak between the pump
body and the motor
The mechanical lining is damaged or defec ve, replace
The pump heats up and
switches off
The motor is overhea ng due to too li le ven la on. Check that there is enough clear
space around the motor.
There is an electrical fault. Check the power connec ons and check the mains
voltage, which must not vary.
There is no damage to
the user interface
The cable(s) is(are) damaged or poorly connected in the user interface housing; check
the condi on of these cables.