12
5.2 I Error codes
Number of
fl ashes
Malfunc on Possible causes Solu ons
1 User interface is
defec ve
• The user interface resets
itself constantly
• Check the electrical
connec ons inside the user
interface housing.
• Replace the motor - interface
assembly if necessary.
2 Network sub-
voltage
• The network voltage has
fallen below 180VCA.
• The interface will reset when
the voltage rises over 209VCA
again for at least 6 seconds
3 temperature • Motor temperature too high
(+100°C)
• Motor temperature too low
(-20°C)
• Wait un l normal temperature
condi ons return and restart
the pump.
4 Surge ac va on • The surge protec on has
been ac vated
• Check the electrical supply.
• Restart the pump.
5 Network
overvoltage
• The voltage exceeds 269VCA • The interface will reset when
the voltage returns to a
normal value.
6 Motor sha jammed • Motor start-up impossible
• The motor has stopped
• Break the pump circuit
and check that no debris is
blocking the turbine (remove
the pre- fi lter screen).
• Check that there is no debris
blocking the rear fan.
7 Automa c
verifi ca on
• At least one of the automa c
tests failed on start-up or
during opera on
• Break the pump circuit then
reconnect it to reset it.
8 Motor fault • At least one of the phases is
disconnected
• Check the electrical
connec ons inside the user
interface housing.