EasyManua.ls Logo

Zodiac FloPro e3 - Error Code Reference

Zodiac FloPro e3
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
5.2 I Error codes
Number of
fl ashes
Malfunc on Possible causes Solu ons
1 User interface is
defec ve
• The user interface resets
itself constantly
• Check the electrical
connec ons inside the user
interface housing.
• Replace the motor - interface
assembly if necessary.
2 Network sub-
voltage
• The network voltage has
fallen below 180VCA.
• The interface will reset when
the voltage rises over 209VCA
again for at least 6 seconds
3 temperature • Motor temperature too high
(+100°C)
• Motor temperature too low
(-20°C)
• Wait un l normal temperature
condi ons return and restart
the pump.
4 Surge ac va on • The surge protec on has
been ac vated
• Check the electrical supply.
• Restart the pump.
5 Network
overvoltage
• The voltage exceeds 269VCA • The interface will reset when
the voltage returns to a
normal value.
6 Motor sha jammed • Motor start-up impossible
• The motor has stopped
• Break the pump circuit
and check that no debris is
blocking the turbine (remove
the pre- fi lter screen).
• Check that there is no debris
blocking the rear fan.
7 Automa c
verifi ca on
• At least one of the automa c
tests failed on start-up or
during opera on
• Break the pump circuit then
reconnect it to reset it.
8 Motor fault • At least one of the phases is
disconnected
• Check the electrical
connec ons inside the user
interface housing.