14
❺ Troubleshoo ng
If a problem occurs, before you contact your retailer, please carry out these few simple checks
using the following tables.
If the problem con nues, contact your retailer.
: Ac ons to be performed by a qualifi ed technician only
5.1 I Appliance behaviour
When the cleaner moves forward in
a straight line, it is no longer fl at on
the fl oor.
(To run on the bo om of the pool,
it is normal for the front of the
cleaner to rise)
There is s ll air in the appliance's casing. Repeat the cleaner immersion
opera ons (see § “3.3 Immersing the cleaner”).
• The fi lter is full or dirty: simply clean it.
• The propeller is damaged, contact your retailer
The cleaner does not or no longer
climbs the pool sides as it originally
did.
(Its electronic programme
means that the cleaner does not
systema cally climb the walls).
• The fi lter is full or dirty: simply clean it.
The lter is clogged: clean it with an acidic solu on (spirit vinegar, for example),
or replace it where necessary.
Even though the water seems clear, microscopic algae are present in your
pool, they are not visible to the naked eye, and they make the sides slippery
and prevent the cleaner from climbing. Carry out shock chlorina on and slightly
reduce the pH. Do not leave the cleaner in the water during shock treatment.
If the problem con nues contact your retailer
The cleaner does not move on
start-up.
Check that the outlet to which the control box is connected is receiving
a power supply.
• Check that the cleaning cycle has been launched and that the light is on.
If the problem con nues contact your retailer
The cable gets tangled
The cleaner doesn't clean the en re
pool
The cleaner's discharge nozzles
become blocked
• Check that you place as much of the fl oa ng cable as possible in the water.
• Stop the fi ltra on pump and begin a new cleaning cycle.
Place the control box in the centre of the pool's length, following the safety
condi ons, see “3.4 I Electricity supply connec ons”. If cleaning is not op mal,
vary the loca on of the control box and the place at which the cleaner enters
the pool.
The control box does not respond
to any bu on presses
Unplug the cable from the mains socket, wait 10 seconds and plug it back in
again.
The robot does not lt upwards to
climb the walls
The brush is worn: check the wear indicators “4.3 I Replacing the brush”
and that the brush is properly a ached to its brush support. Replace the brush
where necessary.
The pool is led with a right angle between the bo om and the walls: the
brush may require adapta on to op mise cleaning: contact your retailer
The cleaner climbs the walls slowly
and stops under the water line
The cleaner climbs the walls
quickly and goes past the water
line, aspira ng air
The cleaner may behave diff erently depending on the lining of the pool.
A parameter may require changing. To do this, contact your retailer

Other manuals for Zodiac TornaX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zodiac TornaX and is the answer not in the manual?

Zodiac TornaX Specifications

General IconGeneral
BrandZodiac
ModelTornaX
CategorySwimming Pool Vacuum
LanguageEnglish

Related product manuals